Difference between revisions of "IP Flush Master and IP Flush Handset compatibility"
From Zenitel Wiki
Line 30: | Line 30: | ||
− | + | {{Note| The option to use the headset input also for handset is a workaround available in AlphaCom-mode only}} | |
[[Category: Station Troubleshooting]] | [[Category: Station Troubleshooting]] |
Latest revision as of 13:12, 25 June 2020
There are two main hardware revisions of the Handset 1008097100 for IP Flush Master stations. Compatibility with the IP Flush Master station is as follows:
Handset revision 1008097100.0300 or newer (from May 2013)
- Used with IP Flush Master revision 1008031000.0400 or newer: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station.
- Used with IP Flush Master revision 1008031000.0301 or older:
- Update the software of the IP Flush Master to version 02.3.3.1 or later
- Log on to the StationWeb. In Advanced Configuration -> Audio, enable the flag “Handset in Headset Slot”
- Connect the Handset to the HEADSET-connector of the station
Handset revision 1008097100.0201 or older
- Used with IP Flush Master revision 1008031000.0301 or older: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station.
- Used with IP Flush Master revision 1008031000.0400 or newer:
- Upgrade the handset to revision 0300 by dismantling the handset by unscrewing the two screws, flip the circuit board over and solder a strap as shown in the image.
- Connect the handset to the handset connector of the station.
About noise in the ear-piece of the handset
When handset revision 1008097100.0201 or older is used with IP Flush Master revision 1008031000.0301 or older, one might experience noise in the ear-piece of the handset. This can be improved by upgrading the handset to revision 1008097100.0300, and use the headset connector of the station.
Procedure:
- Dismantle the handset by unscrewing the two screws
- Flip the circuit board over and solder a strap as shown in the image
- Update the software of the IP Flush Master to version 02.3.3.1 or later
- Log on to the StationWeb. In Advanced Configuration -> Audio, enable the flag “Handset in Headset Slot”
- Connect the handset to the HEADSET-connector of the station