{{APS}}This procedure is applicable for:
+
{{APS}}This procedure is applicable for the [[IP Heavy Duty Station|IP Heavy Duty station 1008072xx0]]
* IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]]
 
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
 
* [[IP Heavy Duty Station|IP Heavy Duty station 1008072xx0]]
 
  
 
+
The Factory Default can be either set to '''Static''' IP 169.254.1.100 or activate '''DHCP'''.
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.
 
  
 
Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
 
Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.

Revision as of 14:09, 17 March 2017

APS.png

This procedure is applicable for the IP Heavy Duty station 1008072xx0

The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.

Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.

Load Defaults without KEY.PNG


Restore with Static IP

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 2 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
  5. Release the button and the station kit will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100
  • Username: admin
  • Password: alphaadmin

Restore with Activated DHCP

The DHCP option is available from software version 01.07.

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 4 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
  5. Release the button and the station kit will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: From DHCP server
  • Username: admin
  • Password: alphaadmin