Difference between revisions of "IP Heavy Duty - Restore Factory Defaults"
From Zenitel Wiki
(→Restore with Static IP) |
|||
Line 10: | Line 10: | ||
== Restore with Static IP == | == Restore with Static IP == | ||
− | # While pressing the button, power up the station | + | # While pressing the button, power up the station and keep the button pressed. |
− | # | + | # Release the button after exactly 2 flashes of the LED. |
− | # Let the LED | + | # Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again. |
− | # Keep the button pressed until the LED | + | # Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset. |
− | # Release the button and the station | + | # Release the button and the station will restart with the factory default settings. |
Factory default values: | Factory default values: | ||
*Station Mode: '''Pulse''' | *Station Mode: '''Pulse''' | ||
− | *Station IP address: '''169.254.1.100''' | + | *Station IP address: '''169.254.1.100''' or '''DHCP''' |
*Username: '''admin''' | *Username: '''admin''' | ||
*Password: '''alphaadmin''' | *Password: '''alphaadmin''' |
Revision as of 14:14, 17 March 2017
This procedure is applicable for the IP Heavy Duty station 1008072xx0
- The Factory Default can be either set to Static IP address 169.254.1.100 or one can activate DHCP.
- Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
Restore with Static IP
- While pressing the button, power up the station and keep the button pressed.
- Release the button after exactly 2 flashes of the LED.
- Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
- Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
- Release the button and the station will restart with the factory default settings.
Factory default values:
- Station Mode: Pulse
- Station IP address: 169.254.1.100 or DHCP
- Username: admin
- Password: alphaadmin
Restore with Activated DHCP
The DHCP option is available from software version 01.07.
- While pressing the button, power up the station kit.
- When the station kit LED starts blinking, release the button after exactly 2 blinks.
- Let the LED blink for exactly 4 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
- Release the button and the station kit will restart with the factory default settings.
Factory default values:
- Station Mode: Pulse
- Station IP address: From DHCP server
- Username: admin