Actions

Difference between revisions of "IP Heavy Duty - Restore Factory Defaults"

From Zenitel Wiki

m (1 revision imported)
 
(7 intermediate revisions by one other user not shown)
Line 1: Line 1:
 
{{APS}}  
 
{{APS}}  
[[File:IP HeavyDuty.png|thumb|250px|The IP Heavy Duty Stations]]
 
 
This procedure is applicable for the [[IP Heavy Duty Station|IP Heavy Duty station 1008072xx0]]
 
This procedure is applicable for the [[IP Heavy Duty Station|IP Heavy Duty station 1008072xx0]]
  
*The Factory Default can be either set to '''Static''' IP address 169.254.1.100 or one can activate '''DHCP'''.
+
The unit can be set to use either '''Static IP''' or '''DHCP'''. On the rear side of the PCB there is a red status LED. You won’t be able to see the actual LED, but you can see the red light from it. Pay attention to this LED during the restore procedure:
*Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
 
  
[[File:Load Defaults without KEY.PNG|left]]
+
[[File:Load Defaults without KEY.PNG|right|thumb|800px|Connect a push button between pins 1 and 4]]
<br style="clear:both;" />
 
  
== Restore with Static IP ==
+
# Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
# While pressing the button, power up the station kit.
+
# While pressing the button, power up the station and keep the button pressed.
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''.
+
# Release the button '''after exactly 2 flashes''' of the LED.
# Let the LED blink for '''exactly 2 more times''', then press the button again.
+
# Let the LED flash for '''exactly 2 more times''' (Static IP) or '''exactly 4 more times''' (DHCP), then press the button again.
# Keep the button pressed until the LED '''blinks fast 2 times''' indicating a successful reset with static IP.
+
# Keep the button pressed until the LED '''flashes fast 2 time'''s (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
# Release the button and the station kit will restart with the factory default settings.
+
# Release the button and the station will restart with the factory default settings.
  
 
Factory default values:
 
Factory default values:
 
*Station Mode: '''Pulse'''
 
*Station Mode: '''Pulse'''
*Station IP address: '''169.254.1.100'''
+
*Station IP address: '''169.254.1.100''' or '''DHCP'''
*Username: '''admin'''
 
*Password: '''alphaadmin'''
 
 
 
== Restore with Activated DHCP ==
 
The DHCP option is available from software version 01.07.
 
# While pressing the button, power up the station kit.
 
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''.
 
# Let the LED blink for '''exactly 4 more times''', then press the button again.
 
# Keep the button pressed until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP.
 
# Release the button and the station kit will restart with the factory default settings.
 
 
 
Factory default values:
 
*Station Mode: '''Pulse'''
 
*Station IP address: '''From DHCP server'''
 
 
*Username: '''admin'''
 
*Username: '''admin'''
 
*Password: '''alphaadmin'''
 
*Password: '''alphaadmin'''

Latest revision as of 15:10, 5 February 2018

APS.png

This procedure is applicable for the IP Heavy Duty station 1008072xx0

The unit can be set to use either Static IP or DHCP. On the rear side of the PCB there is a red status LED. You won’t be able to see the actual LED, but you can see the red light from it. Pay attention to this LED during the restore procedure:

Connect a push button between pins 1 and 4
  1. Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
  2. While pressing the button, power up the station and keep the button pressed.
  3. Release the button after exactly 2 flashes of the LED.
  4. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  5. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  6. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 or DHCP
  • Username: admin
  • Password: alphaadmin