Actions

Difference between revisions of "IP Hotline Connections"

From Zenitel Wiki

(Created page with "== Introduction == The table below is an overview of the main connectors involved when installing the IP Hotline Station. {| border="1" |- | align=left | LAN (P1) || 10/100 M...")
 
(Network Connection)
Line 22: Line 22:
  
 
See Related Article [[INCA Master Station Kit Board Connectors]] for local power supply connections.
 
See Related Article [[INCA Master Station Kit Board Connectors]] for local power supply connections.
 
== Network Connection ==
 
There are two RJ45 ports on the IP Stations:
 
:* LAN port: for connecting to the network and the AlphaCom XE Audio Server.
 
:* AUX port: for connecting to auxiliary equipment such as a PC or IP Camera.
 
 
{|
 
|[[Image:IP_Master_Rear_View.PNG|thumb|200px|IP Flush Master, IP OR, IP Master Kit - Rear view]]
 
|}
 
  
 
== Input/Output Connections ==
 
== Input/Output Connections ==

Revision as of 12:14, 25 October 2016

Introduction

The table below is an overview of the main connectors involved when installing the IP Hotline Station.

LAN (P1) 10/100 Mbps RJ45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
AUX (P2) 10/100 Mbps RJ45 port for auxilliary equipment such as PC or IP Camera.
Input/Output Pluggable screw terminal
Local Power Pluggable screw terminal, 17-27 VDC Idle 4W, max. 8W

To access these connectors the front cover must be removed.

Power Supply

The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.

If PoE is not available, the IP Hotline Station can be connected to a 24 VDC local power supply.

See Related Article INCA Master Station Kit Board Connectors for local power supply connections.

Input/Output Connections

There are I/O connection options for all IP Stations, except the IP Desktop Station and the IP Dual Display Station. These I/O connections include:

  • 3 digital inputs (P4)
  • 1 logical output (TP9)
  • 1 relay output (P3)


These connections are used as relay contacts for door lock control and external I/O devices. For pin settings on the P3 and P4 connectors on the station board, see See Related Article IP Station Board Connections and Indications.