Difference between revisions of "IP Master Station Kit Restore Factory Defaults"
From Zenitel Wiki
(→Factory default values) |
|||
Line 17: | Line 17: | ||
== Factory default values == | == Factory default values == | ||
− | *Station Mode: ''' | + | *Station Mode: '''Edge''' |
*Station IP address: '''169.254.1.100''' or '''DHCP''' | *Station IP address: '''169.254.1.100''' or '''DHCP''' | ||
*Username: '''admin''' | *Username: '''admin''' |
Latest revision as of 12:25, 24 October 2023
This procedure is applicable for:
- IP Master Station Kit 100849300
The unit can be set to use either Static IP or DHCP. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:
Procedure
- Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
- While pressing the button, power up the station kit and keep the button pressed.
- Release the button after exactly 2 flashes of the LED.
- Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
- Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
- Release the button and the station will restart with the factory default settings.
Factory default values
- Station Mode: Edge
- Station IP address: 169.254.1.100 or DHCP
- Username: admin
- Password: alphaadmin