This procedure is applicable for the [[School IP Intercom - 1402001000|IP School Intercom Station]].
 +
[[File:SchoolIndications1.png|right|300px]]
 +
'''Procedure:'''<br>
 +
When loading factory defalt settings, the unit can be set to use either '''Static IP''' or '''DHCP'''.
 +
[[File:Load Defaults without Display - 1.PNG|right|200px]]
 +
[[File:Load Defaults without Display - 2.PNG|right|200px]]
 +
# While pressing the call button, power up the station and keep the button pressed.
 +
# Release the button '''after exactly 2 flashes''' of the LED.
 +
# Let the LED flash for '''exactly 2 more times''' (Static IP) or '''exactly 4 more times''' (DHCP), then press the button again.
 +
# Keep the button pressed until the LED '''flashes fast 2 time'''s (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
 +
# Release the button and the station will restart with the factory default settings.
 +
 +
'''Factory default values:'''
 +
*Station Mode: '''Pulse'''
 +
*Station IP address: '''169.254.1.100''' (Static) or '''DHCP'''
 +
*Username: '''admin'''
 +
*Password: '''alphaadmin'''
 +
 +
 +
* Software 01.06 and earlier: Username/password is '''ADMIN/alphacom'''
 +
 +
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 +
 +
 +
-------------------
 +
 +
 
An IP Station may have to be reset to its original factory default settings if, for instance, the password to the webserver is forgotten.
 
An IP Station may have to be reset to its original factory default settings if, for instance, the password to the webserver is forgotten.
  

Revision as of 14:15, 20 March 2017

APS.png

This procedure is applicable for the IP School Intercom Station.

SchoolIndications1.png

Procedure:
When loading factory defalt settings, the unit can be set to use either Static IP or DHCP.

Load Defaults without Display - 1.PNG
Load Defaults without Display - 2.PNG
  1. While pressing the call button, power up the station and keep the button pressed.
  2. Release the button after exactly 2 flashes of the LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  4. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 (Static) or DHCP
  • Username: admin
  • Password: alphaadmin


* Software 01.06 and earlier: Username/password is ADMIN/alphacom




An IP Station may have to be reset to its original factory default settings if, for instance, the password to the webserver is forgotten.

The defaults can be either be set to Static IP or Activated DHCP.

This procedure is the recommended procedure for the IP School Intercom Station.

The Factory Default procedure can be used to either set the station to use a Static IP address, or to use IP address from a DHCP server.

Restore with Static IP

SchoolIndications1.png
  1. While pressing the emergency call button, power up the station.
  2. When the station green LED starts blinking, release the emergency call button after exactly 2 blinks.
  3. Let the LED blink for exactly 2 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
  5. Release the button and the substation will restart with the factory default settings.
Factory default values
Station Mode Pulse
Station IP address 169.254.1.100
AlphaCom IP address 169.254.1.5
Username* admin
Password* alphaadmin
* Software 01.06 and earlier: ADMIN/alphacom)

Restore with Activated DHCP

The DHCP option is available from software version 01.07.

  • While pressing the emergency call button, power up the station.
  • When the station green LED starts blinking, release the emergency call button after exactly 2 blinks.
  • Let the LED blink for exactly 4 more times, then press the button again.
  • Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
  • Release the button and the station will restart with the factory default settings.
Factory default values
Station Mode Pulse
Station IP address determined by DHCP server
AlphaCom IP address 169.254.1.5
Username* admin
Password* alphaadmin
* Software 01.06 and earlier: ADMIN/alphacom)