Actions

Difference between revisions of "IP School Intercom Station Restore Factory Defaults"

From Zenitel Wiki

 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
{{APS}}  
 
{{APS}}  
This procedure is applicable for the [[School IP Intercom - 1402001000|IP School Intercom Station]].
+
{{note|This procedure is applicable for the [[School IP Intercom - 1402001000]].}}
 
[[File:SchoolIndications1.png|right|300px]]
 
[[File:SchoolIndications1.png|right|300px]]
 
'''Procedure:'''<br>
 
'''Procedure:'''<br>
This procedure will load factory defalt settings. The unit can be set to use either '''Static IP''' or '''DHCP'''.  
+
This procedure will load factory defalt settings in the station. The unit can be set to use either '''Static IP''' or '''DHCP'''.  
 
# While pressing the '''emergency button''', power up the station and keep the button pressed.
 
# While pressing the '''emergency button''', power up the station and keep the button pressed.
 
# Release the button '''after exactly 2 flashes''' of the LED.
 
# Release the button '''after exactly 2 flashes''' of the LED.
Line 16: Line 16:
 
*Password: '''alphaadmin'''
 
*Password: '''alphaadmin'''
  
 
* Software 01.06 and earlier: Username/password is '''ADMIN/alphacom'''
 
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
 
 
-------------------
 
 
 
An IP Station may have to be reset to its original factory default settings if, for instance, the password to the webserver is forgotten.
 
 
The defaults can be either be set to Static IP or Activated DHCP.
 
 
This procedure is the recommended procedure for the [[School IP Intercom - 1402001000|IP School Intercom Station]].
 
 
The Factory Default procedure can be used to either set the station to use a Static IP address, or to use IP address from a DHCP server.
 
 
=== Restore with Static IP ===
 
[[File:SchoolIndications1.png|right|300px]]
 
# While pressing the emergency call button, power up the station.
 
# When the station green LED starts blinking, release the emergency call button '''after exactly 2 blinks'''.
 
# Let the LED blink for '''exactly 2 more times''', then press the button again.
 
# Keep the button pressed until the LED '''blinks fast 2 times''' indicating a successful reset with static IP.
 
# Release the button and the substation will restart with the factory default settings.
 
 
{| class="wikitable"
 
!style="background:#ffdead" colspan="2"|Factory default values
 
|-
 
| Station Mode || align=center | '''Pulse'''
 
|-
 
| Station IP address || align=center | '''169.254.1.100'''
 
|-
 
| AlphaCom IP address || align=center | '''169.254.1.5'''
 
|-
 
| Username* || align=center | '''admin'''
 
|-
 
| Password* || align=center | '''alphaadmin'''
 
|-
 
|}
 
 
* Software 01.06 and earlier: '''ADMIN/alphacom''')
 
 
=== Restore with Activated DHCP ===
 
The DHCP option is available from software version 01.07.<br/>
 
* While pressing the emergency call button, power up the station.
 
* When the station green LED starts blinking, release the emergency call button '''after exactly 2 blinks'''.
 
* Let the LED blink for '''exactly 4 more times''', then press the button again.
 
* Keep the button pressed until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP.
 
* Release the button and the station will restart with the factory default settings.
 
 
{| class="wikitable"
 
!style="background:#ffdead" colspan="2"|Factory default values
 
|-
 
| Station Mode || align=center | '''Pulse'''
 
|-
 
| Station IP address || align=center | '''determined by DHCP server'''
 
|-
 
| AlphaCom IP address || align=center | '''169.254.1.5'''
 
|-
 
| Username* || align=center | '''admin'''
 
|-
 
| Password* || align=center | '''alphaadmin'''
 
|-
 
|}
 
 
* Software 01.06 and earlier: '''ADMIN/alphacom''')
 
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Latest revision as of 17:24, 31 January 2023

APS.png
Note icon This procedure is applicable for the School IP Intercom - 1402001000.


SchoolIndications1.png

Procedure:
This procedure will load factory defalt settings in the station. The unit can be set to use either Static IP or DHCP.

  1. While pressing the emergency button, power up the station and keep the button pressed.
  2. Release the button after exactly 2 flashes of the LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  4. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 (Static) or DHCP
  • Username: admin
  • Password: alphaadmin