Actions

Difference between revisions of "IP School Intercom Station Restore Factory Defaults"

From Zenitel Wiki

 
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
{{APS}}  
 
{{APS}}  
This procedure is applicable for the [[School IP Intercom - 1402001000|IP School Intercom Station]].
+
{{note|This procedure is applicable for the [[School IP Intercom - 1402001000]].}}
 
[[File:SchoolIndications1.png|right|300px]]
 
[[File:SchoolIndications1.png|right|300px]]
 
'''Procedure:'''<br>
 
'''Procedure:'''<br>
Line 16: Line 16:
 
*Password: '''alphaadmin'''
 
*Password: '''alphaadmin'''
  
 
* Software 01.06 and earlier: Username/password is '''ADMIN/alphacom'''
 
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Latest revision as of 17:24, 31 January 2023

APS.png
Note icon This procedure is applicable for the School IP Intercom - 1402001000.


SchoolIndications1.png

Procedure:
This procedure will load factory defalt settings in the station. The unit can be set to use either Static IP or DHCP.

  1. While pressing the emergency button, power up the station and keep the button pressed.
  2. Release the button after exactly 2 flashes of the LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  4. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 (Static) or DHCP
  • Username: admin
  • Password: alphaadmin