(15 intermediate revisions by 2 users not shown) |
Line 1: |
Line 1: |
− | The IP substation board supports input for digits 0 - 9, 10 [[DAK|DAK-keys]], as well as [[M-key]] and [[C-key]].
| + | #REDIRECT [[INCA Substation Board Connectors]] |
− | The inputs are available on soldering pads on the substation PCB.
| |
− | | |
− | Inputs for DAK-keys, M- and C-key:
| |
− | DAK 1: N115 + N112
| |
− | DAK 2: N115 + N113
| |
− | DAK 3: N115 + N114
| |
− | DAK 4: N105 + N110
| |
− | DAK 5: N105 + N111
| |
− | DAK 6: N105 + N112
| |
− | DAK 7: N105 + N113
| |
− | DAK 8: N105 + N114
| |
− | DAK 9: N105 + N115
| |
− | DAK 10: N106 + N110
| |
− | -------------------
| |
− | M-key: N115 + N111
| |
− | C-key: N115 + N110
| |
− | | |
− | If more than 10 DAK keys are needed, it is possible to use the digit keys as DAK keys. This is enabled by the flag "Digit Key is DAK" in the [[Users_%26_Stations_%28AlphaPro%29#Station_Type|Users & Stations > Station Type]] menu in AlphaPro. The regular DAK keys are then moved to DAK 11 - 20.
| |
− | | |
− | Inputs for digit keys:
| |
− | Digit 0: N111 + N110
| |
− | Digit 1: N112 + N110
| |
− | Digit 2: N112 + N111
| |
− | Digit 3: N113 + N110
| |
− | Digit 4: N113 + N111
| |
− | Digit 5: N113 + N112
| |
− | Digit 6: N114 + N110
| |
− | Digit 7: N114 + N111
| |
− | Digit 8: N114 + N112
| |
− | Digit 9: N114 + N111
| |
− | | |
− | | |
− | | |
− | KEY0 = N110
| |
− | KEY1 = N111
| |
− | KEY2 = N112
| |
− | KEY3 = N113
| |
− | KEY4 = N114
| |
− | KEY5 = N115
| |
− | KEY6 = N105
| |
− | KEY7 = N106
| |
− | KEY8 = N107
| |