== Station LED (on board and in front plate) ==
 
'''Blinking 1 sec. interval''': Station does not have connection to the AlphaCom E exchange.
 
:''Possible reasons'':
 
:* No connection to Ethernet
 
:* Wrong AlphaCom E IP address configured
 
:* Invalid IP address
 
:* No or wrong gateway to the AlphaCom E exchange
 
 
'''Blinking 5 sec. interval''': Station has connection to the AlphaCom E exchange, but has not been registered.
 
:''Reason'':
 
:* Station has not been programmed in AlphaPro
 
 
 
'''No blinking'''
 
:''Possible reasons'':
 
:* Station connected and registered to the AlphaCom E exchange - All OK
 
:* Station not powered up (if no other LEDs are active)
 
 
 
== Status LED ==
 
Blinking 2 red + 1 green Station does not have connection to the AlphaCom E exchange
 
Blinking 1 red + 2 green Station has connection to AlphaCom E exchange, but has not been
 
registered
 
Blinking 3 green Station connected and registered in the AlphaCom E exchange
 
LAN LEDs (on LAN and AUX RJ45-jacks):
 
Left green LED:
 
- Steady light Ethernet connection OK
 
- Blinking Ethernet traffic
 
- No light No Ethernet connection
 
Right amber LED:
 
- Light 100 Mbit Ethernet connection
 
- No light 10 Mbit Ethernet connection
 
 
 