Actions

Difference between revisions of "Light Industrial Master Station with Loudspeaker - 1007080000"

From Zenitel Wiki

(Handset connection)
(Handset troubleshooting)
Line 34: Line 34:
 
A component must be changed on the station PCB; A100C01433, in order to make the converstion cancel. Change capacitor C14 (47µF/100V) to 4,7µF/63V. <br>
 
A component must be changed on the station PCB; A100C01433, in order to make the converstion cancel. Change capacitor C14 (47µF/100V) to 4,7µF/63V. <br>
 
[[File:7080_handset_cancel.PNG|thumb|left|500px]]
 
[[File:7080_handset_cancel.PNG|thumb|left|500px]]
 +
<br style="clear:both;" />
  
 
== Dimensional drawing ==
 
== Dimensional drawing ==

Revision as of 09:23, 23 February 2016

Light Industrial Master Station

Highlights

  • Fully equipped splashproof master station with free access to all extensions and features
  • Flame- and chip-resistant plastic casing. Key board foil of UV-cured PVC. Resistant to corrosive fluids
  • Electret microphone and red microphone live lamp
  • Screw terminals for easy connection of installation cables
  • Built-in loudspeaker and possibility to connect an external speaker. Sound level adjustable with a potentiometer inside the station
  • Built-in 10W (8 Ohm) VOX operated power amplifier for external loudspeaker

Additional Documentation

For more documentation please see http://www.zenitel.com/product/light-industrial-master-station

Installation

Light Industrial Master Station with Loudspeaker 100 7080 000 Installation.jpg


Connections

Industrial Analogue Connections.png


Handset connection

When handset is connected, open shunt S8 and S11.

7080 handset conn.PNG


Handset troubleshooting

Symptom:

When an industrial station type 100 7080 000 is equipped with a handset there is a knows issue related to the handset operation: when the handset is replaced (on-hook) during conversation, the conversation does not cancel.

Solution:

A component must be changed on the station PCB; A100C01433, in order to make the converstion cancel. Change capacitor C14 (47µF/100V) to 4,7µF/63V.

7080 handset cancel.PNG


Dimensional drawing

Light Industrial Master Station with Loudspeaker 100 7080 000 Description.jpg