Actions

Light Industrial Master Station with Loudspeaker - 1007080000

From Zenitel Wiki

Revision as of 14:03, 10 January 2017 by Roarl (talk)
AlphaCom icon 300px.png
Light Industrial Master Station

Highlights

  • Fully equipped splashproof master station with free access to all extensions and features
  • Flame- and chip-resistant plastic casing. Key board foil of UV-cured PVC. Resistant to corrosive fluids
  • Electret microphone and red microphone live lamp
  • Screw terminals for easy connection of installation cables
  • Built-in loudspeaker and possibility to connect an external speaker. Sound level adjustable with a potentiometer inside the station
  • Built-in 10W (8 Ohm) VOX operated power amplifier for external loudspeaker

Dimensional Drawing

1007080000-dimensions 0.jpg

Connections

For server end connection details see ASLT - AlphaCom Subscriber Line Board

Industrial Analogue Connections.png


Handset connection

When handset is connected, open shunt S8 and S11.

7080 handset conn.PNG


Handset troubleshooting

Symptom:

When an industrial station type 100 7080 000 is equipped with a handset there is a knows issue related to the handset operation: when the handset is replaced (on-hook) during conversation, the conversation does not cancel.

Solution:

A component must be changed on the station PCB; A100C01433, in order to make the converstion cancel. Change capacitor C14 (47µF/100V) to 4,7µF/63V.

7080 handset cancel.PNG