Actions

Difference between revisions of "MST - Mail to Station"

From Zenitel Wiki

(Syntax)
 
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{{AI}}
 +
<br>
 
== Syntax ==
 
== Syntax ==
  
Line 5: Line 7:
 
*Node: 1-254 (optional)
 
*Node: 1-254 (optional)
 
*Destination phys. no: 1-552
 
*Destination phys. no: 1-552
*Source phys. no: 1-552
+
*Source phys. no: 1-552, or 0 if no source
 
*Mail text: Free text  (maximum 16 characters) in quotes, or [[Predefined AlphaCom mails]] id: 19-30  
 
*Mail text: Free text  (maximum 16 characters) in quotes, or [[Predefined AlphaCom mails]] id: 19-30  
 
*Priority: 1-255 (optional)
 
*Priority: 1-255 (optional)

Latest revision as of 16:15, 4 October 2019

AI.png


Syntax

MST  <[(node)]>  <destination phys. no>  <source phys. no>  <“mail-text”/mail-id> <[priority]>
  • Node: 1-254 (optional)
  • Destination phys. no: 1-552
  • Source phys. no: 1-552, or 0 if no source
  • Mail text: Free text (maximum 16 characters) in quotes, or Predefined AlphaCom mails id: 19-30
  • Priority: 1-255 (optional)

Examples

MST 47 0 "Temp. alarm"           – Send textmessage "Temp.alarm" to station 47
MST (3) 47 0 "Temp. alarm" 160   – Send "Temp.alarm" with priority 160 to station 47 in node 3
MST 1 0 28                       - Send line error (28) to station 1