Actions

Difference between revisions of "MST - Mail to Station"

From Zenitel Wiki

Line 7: Line 7:
 
*Source phys. no: 1-552
 
*Source phys. no: 1-552
 
*Mail text: Free text  (maximum 16 characters) in quotes, or Mail id: no 19-30 (see below)
 
*Mail text: Free text  (maximum 16 characters) in quotes, or Mail id: no 19-30 (see below)
*Priority: 1-255
+
*Priority: 1-255 (optional)
  
 
Mail id's:
 
Mail id's:

Revision as of 14:26, 10 January 2008

Syntax

MST  <[(node)]>  <destination phys. no>  <source phys. no>  <“mail-text”/mail-id> <[priority]>
  • Node: 1-254 (optional)
  • Destination phys. no: 1-552
  • Source phys. no: 1-552
  • Mail text: Free text (maximum 16 characters) in quotes, or Mail id: no 19-30 (see below)
  • Priority: 1-255 (optional)

Mail id's:

Mail id Mail Text
19 Technical Alarm 1
20 Technical Alarm 2
21 Technical Alarm 3
22 Power Supply 3
23 Power Supply 2
24 Power Supply 1
25 Standby Active
26 Temperature Alarm
27 Board error
28 Line Error
29 Device Error
30 AGA Error

Example

MST 47 0 “Temp. alarm”           – Send textmessage "Temp.alarm" to station 47
MST (3) 47 0 “Temp. alarm” 160   – Send "Temp.alarm" with priority 160 to station 47 in node 3
MST 1 0 28                       - Send line error (28) to station 1