Actions

Main Settings (IP Stations)

From Zenitel Wiki

Revision as of 12:55, 28 February 2019 by Roarl (talk | contribs)
APS.png
SIP-MainSettings.PNG


Station Mode: Select one of the available modes: AlphaCom, Exigo, SIP, Pulse and Pulse Server.

Product Model And Accessory [Turbine only]: Depending on the type of Turbine hardware, there are different Product models and accessories to choose from. Find your model here: Turbine Station Models

IP Settings:

  • DHCP – Select this option if the IP station shall receive IP Settings from a DHCP server.
  • Static IP – Select this option if the IP station shall use a static IP address. Enter values for:
- IP-address
- Subnet-mask
- Gateway
- DNS Server 1 (option for network administration)
- DNS Server 2 (option for network administration)
- Hostname (option for network administration)
  • Disable Reset to Factory default settings using frontboard and I/O [Turbine only]: If enabled, factory reset will only be possible from StationWeb. This is disabled by default.
  • Read IP Address [Turbine only]: Check the Read IP Address box to enable an unregistered station to speak the IP address when the call button is pressed. "Read IP Address" is default enabled.
  • Enable RSTP [Turbine only] (for Industrial & Ex stations): Check the Enable RSTP box to enable RSTP. RSTP is only required when using redundant networking
  • Ethernet Speed 10 Mbits/s [Turbine only]: Enable in some rare cases where it is not convenient to use 100 MBit/s Ethernet speed. Default Ethernet speed is 100 Mbit/s unless switch is configured to 10 Mbit/s.
  • Use Last IP On DHCP failure [INCA only]: If the station does not receive an IP Address from a DHCP server at startup, it will use the last IP address.
  • IGMP Version [INCA only]: Select IGMPv2 or IGMPv3 for multicast group membership.

Click Save followed by Apply to apply the new configuration settings.