Actions

Node

From Zenitel Wiki

Revision as of 23:17, 19 June 2007 by Asle (talk)

All ACDP data messages are addressed to a device. A device is always related to (owned by) a node. A full device address consists of <node> <device>.
<Node> is one byte.

Value (decimal) Value (Hex) Node Type
0 0x00 Node 0 is interpreted by the exchange which receives it as “own node”, and it will replace the value 0 with it’s own node number before processing takes place.

Response messages will thus NOT contain any node 0 references

1 - 64 0x01 - 0x40 External boxes. RIOs, PCs etc.