All ACDP data messages are addressed to a device. A device is always related to (owned by) a node. A full device address consists of <node> <device>.
<Node> is one byte.

Value (decimal) Value (Hex) Node Type
0 0x00 Node 0 is interpreted by the exchange which receives it as "own node", and it will replace the value 0 with it’s own node number before processing takes place.

Response messages will thus NOT contain any node 0 references

1 - 254 0x01 - 0xFE Exchanges in AlphaNet
255 0xFF Broadcast to all nodes

- All AlphaNet nodes will re-send messages addressed to 0xFF to all other AlphaNet signaling links. - The Network layer manages broadcast messages to avoid excessive signaling traffic and discards messages that has jumped too many times.