Line 8: Line 8:
 
|'''Feature number''': || 80
 
|'''Feature number''': || 80
 
|-valign="top
 
|-valign="top
|'''Parameter 1''': || 0 = Open<br> 1= Private
+
|'''Parameter 1''': || 0 = Open (7886)<br> 1 = Private (7887)
 
|-valign="top"  
 
|-valign="top"  
 
|'''Description''': || Feature for activating [[Transfer_Features#Follow_Me|Follow me]] (e.g. remote Call Forwarding)
 
|'''Description''': || Feature for activating [[Transfer_Features#Follow_Me|Follow me]] (e.g. remote Call Forwarding)

Revision as of 23:16, 28 January 2008

Feature: Follow Me
Default directory number: 7886, 7887
Feature number: 80
Parameter 1: 0 = Open (7886)
1 = Private (7887)
Description: Feature for activating Follow me (e.g. remote Call Forwarding)

Procedure: On the remote station, dial 72 + own station number to forward calls to the remote station.

See also: Call Forwarding

Alternative way to select call mode OPEN. Procedure: Dial 7886. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). Configuration: There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware. (User/More../Programmable Open/Private). Application: • Fixed functionality often required, where the station must ignore the PRIVATE switch. • EMC problems with PRIVATE switch in wall stations. Now solved by removing the switch, and use keypad for PRIVATE mode. Version: AMC 06.00 DirNo: 7886 Feature: 80/0 (Db ref. 587) 3.1.7. Feature idle: Set station PRIVATE Alternative way to select call mode PRIVATE. Procedure: Dial 7887. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). Configuration: There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware. (User/More../Programmable Open/Private). Application: • Fixed functionality often required, where the station must ignore the PRIVATE switch. • EMC problems with PRIVATE switch in wall stations. Now solved by removing the switch, and use keypad for PRIVATE mode.


80 FEAT_OPEN_PRIVATE

Param1 Description
?? Toggle functional OPEN/PRIVATE on station
Alternative to mechanical PRIVATE switch.

Mode 0 = OPEN.

Mode 1 = PRIVATE (must be enabled per station).