Actions

Difference between revisions of "Open / Private selection feature"

From Zenitel Wiki

Line 2: Line 2:
 
|-
 
|-
 
|width="170pt"|'''Feature''':
 
|width="170pt"|'''Feature''':
| Follow Me
+
| Programmable Open/Private
 
|-
 
|-
 
|'''Default directory number''': || 7886, 7887
 
|'''Default directory number''': || 7886, 7887
Line 10: Line 10:
 
|'''Parameter 1''': || 0 = Open (7886)<br> 1 = Private (7887)
 
|'''Parameter 1''': || 0 = Open (7886)<br> 1 = Private (7887)
 
|-valign="top"  
 
|-valign="top"  
|'''Description''': || Feature for activating [[Transfer_Features#Follow_Me|Follow me]] (e.g. remote Call Forwarding)
+
|'''Description''': || Feature codes for setting the station in Open or Private mode. To use these codes, the station must first be enabled for this feature in AlphaPro, Users & Stations -> Station Type -> Programmable Open/Private.
Procedure: On the remote station, dial 72 + own station number to forward calls to the remote station.
+
 
<br><br>
+
Additional information:
See also: [[Transfer_Features#Call_Forwarding|Call Forwarding]]
+
* By default the Open/Private status is decided by the station hardware by means of a Open/Private switch on the station.
 +
* Alternative to mechanical PRIVATE switch.
 +
 
 +
 
  
 
|}
 
|}
Alternative way to select call mode OPEN.
+
 
 
Procedure:  Dial 7886.  If the feature is allowed, a success tone is heard, else a failure tone.  The setting is permanent (stored in NVRAM, survives reset).
 
Procedure:  Dial 7886.  If the feature is allowed, a success tone is heard, else a failure tone.  The setting is permanent (stored in NVRAM, survives reset).
 
Configuration:  There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware.  (User/More../Programmable Open/Private).
 
Configuration:  There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware.  (User/More../Programmable Open/Private).
Line 26: Line 29:
 
Alternative way to select call mode PRIVATE.
 
Alternative way to select call mode PRIVATE.
 
Procedure:  Dial 7887.  If the feature is allowed, a success tone is heard, else a failure tone.  The setting is permanent (stored in NVRAM, survives reset).
 
Procedure:  Dial 7887.  If the feature is allowed, a success tone is heard, else a failure tone.  The setting is permanent (stored in NVRAM, survives reset).
Configuration:  There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware.  (User/More../Programmable Open/Private).
+
  (User/More../Programmable Open/Private).
 
Application:
 
Application:
 
• Fixed functionality often required, where the station must ignore the PRIVATE switch.
 
• Fixed functionality often required, where the station must ignore the PRIVATE switch.

Revision as of 23:28, 28 January 2008

Feature: Programmable Open/Private
Default directory number: 7886, 7887
Feature number: 80
Parameter 1: 0 = Open (7886)
1 = Private (7887)
Description: Feature codes for setting the station in Open or Private mode. To use these codes, the station must first be enabled for this feature in AlphaPro, Users & Stations -> Station Type -> Programmable Open/Private.

Additional information:

  • By default the Open/Private status is decided by the station hardware by means of a Open/Private switch on the station.
  • Alternative to mechanical PRIVATE switch.


Procedure: Dial 7886. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset). Configuration: There is a flag in AlphaPro that decide if this station's OPEN/PRIVATE status is controlled by feature codes OR by station hardware. (User/More../Programmable Open/Private). Application: • Fixed functionality often required, where the station must ignore the PRIVATE switch. • EMC problems with PRIVATE switch in wall stations. Now solved by removing the switch, and use keypad for PRIVATE mode. Version: AMC 06.00 DirNo: 7886 Feature: 80/0 (Db ref. 587) 3.1.7. Feature idle: Set station PRIVATE Alternative way to select call mode PRIVATE. Procedure: Dial 7887. If the feature is allowed, a success tone is heard, else a failure tone. The setting is permanent (stored in NVRAM, survives reset).

 (User/More../Programmable Open/Private).

Application: • Fixed functionality often required, where the station must ignore the PRIVATE switch. • EMC problems with PRIVATE switch in wall stations. Now solved by removing the switch, and use keypad for PRIVATE mode.


80 FEAT_OPEN_PRIVATE

Param1 Description
?? Toggle functional OPEN/PRIVATE on station
Alternative to mechanical PRIVATE switch.

Mode 0 = OPEN.

Mode 1 = PRIVATE (must be enabled per station).


Back to feature list