In the AlphaCom XE7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default. The potmeters P5 and P6 are used to adjust the input level. Line points 5 and 6 can also be used as normal subscriber points.
+
In the [[AlphaCom XE7]] the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default. The potmeters P5 and P6 are used to adjust the input level. Line points 5 and 6 can also be used as normal subscriber points.
  
 
* To enable physical number 5 and/or 6 to be used for regular intercom stations:
 
* To enable physical number 5 and/or 6 to be used for regular intercom stations:

Revision as of 17:37, 1 March 2019

In the AlphaCom XE7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default. The potmeters P5 and P6 are used to adjust the input level. Line points 5 and 6 can also be used as normal subscriber points.

  • To enable physical number 5 and/or 6 to be used for regular intercom stations:
  • Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
AlphaCom XE7 backplane


  • In AlphaPro, select Exchange & System -> Boards
  • Change the port setting from ‘Audio program feed’ to ‘Default’
  • Reset the exchange
Set "Port Use" for physical number 5 and 6 to "Default"