By default the physical numbers 5 and 6 on the first [[ASLT|ASLT line board]] in the [[AlphaCom XE7]] are enabled for Audio Program distribution. The potmeters P5 and P6 are used to adjust the input level. Line points 5 and 6 can also be used as normal subscriber points.
+
By default the physical numbers 5 and 6 on the first [[ASLT|ASLT line board]] in the [[AlphaCom XE7]] are enabled for Audio Program distribution. The potmeters P5 and P6 are used to adjust the input level.  
  
  
 
== Intercom stations ==
 
== Intercom stations ==
To enable physical number 5 and/or 6 to be used for regular intercom stations:
+
By default phys no 5 and 6 are used for Audio Program input. However, it is possible to use these physical numbers for intercom stations instead. To enable physical number 5 and/or 6 to be used for regular intercom stations:
 
* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
 
* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
 
[[Image:ACE7 backplane.jpg|thumb|300px|left|AlphaCom XE7 backplane]]
 
[[Image:ACE7 backplane.jpg|thumb|300px|left|AlphaCom XE7 backplane]]

Revision as of 12:31, 27 August 2020

AlphaCom icon 300px.png

Audio Program inputs

By default the physical numbers 5 and 6 on the first ASLT line board in the AlphaCom XE7 are enabled for Audio Program distribution. The potmeters P5 and P6 are used to adjust the input level.


Intercom stations

By default phys no 5 and 6 are used for Audio Program input. However, it is possible to use these physical numbers for intercom stations instead. To enable physical number 5 and/or 6 to be used for regular intercom stations:

  • Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
AlphaCom XE7 backplane


  • In AlphaPro, select Exchange & System -> Boards
  • Change the port setting from ‘Audio program feed’ to ‘Default’
  • Reset the exchange
Set "Port Use" for physical number 5 and 6 to "Default"