In the AlphaCom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.  
 
In the AlphaCom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.  
 
[[Image:ACE7 backplane.jpg|thumb|300px|AlphaCom E7 backplane]]
 
[[Image:ACE7 backplane.jpg|thumb|300px|AlphaCom E7 backplane]]
[[Image:Board Use default.png|thumb|left|400px|Set physical number 5 and 6 to "Default"]]
+
[[Image:Board Use default.png|thumb|left|400px|Set "Port Use" for physical number 5 and 6 to "Default"]]
 
* To set physical number 5 and/or 6 to be used as normal subscriber ports:
 
* To set physical number 5 and/or 6 to be used as normal subscriber ports:
 
:* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
 
:* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.

Revision as of 15:34, 7 September 2015

In the AlphaCom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.

AlphaCom E7 backplane
Set "Port Use" for physical number 5 and 6 to "Default"
  • To set physical number 5 and/or 6 to be used as normal subscriber ports:
  • Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
  • In AlphaPro, select Exchange & System -> Boards
  • Change the port setting from ‘Audio program feed’ to ‘Default’
  • Reset the exchange