Feature: Set station volume
Default directory number: 783
Feature number: 38
Parameter 1: 0 (N/A)
Description: Set output level (0-9) on ASLT line board. Primarily to compensate for long wires. Dial: 783 + digit 0-9. Default level is 3.


The ASLT output level can also be set from the Users & Stations menu in AlphaPro. The relation between the 783 volume setting and AlphaPro setting is as follows:

AlphaPro  783+n
--------  -----
 -14        0 
 -12	
 -10	
  -8        1
  -6	
  -4        2
  -2	
   0        3  (Default)
   2        4
   4        5
   6        6
   8        7
  10	
  12        8
  14	
  16        9 

Related AlphaCom Data Protocol message: VOL