Actions

Reset and Set Node buttons fail

From Zenitel Wiki

Revision as of 14:09, 11 May 2021 by Asle (talk | contribs)

Problem: In an ICX-500 or ICX-Core system, when using the Reset button or the Set Node button from AlphaPro, the communication to the server fails, and you get an error message.

Error message when pressing the Reset button


Solution: In Exchange & System > System, make sure that the "Node Type" is set to ICX, and not to "AlphaCom" or "AlphaCom XE".

Set "Node Type" = ICX


Reason:

  • When "Node Type" = "AlphaCom/AlphaCom XE, the AlphaPro is using TCP port 60001 for communication with the server. Port 60001 is the port used by AlphaCom, but not supported in the ICX.
  • When "Node Type" = "ICX", the AlphaPro is using TCP port 80 (or 443) for communication with the server. Port 80 is the port used by ICX.