SET_SYSTEM_TIME 0x0027 39 AMC 05.00
$SST W1999 U12 U31 U23 U59 U59 <br\> $SST FFFF FF FF U03 U02 FF
Set a device’s internal clock to the given date and time.
1 CLOCK Date and time<br\>AMC 08.01: Use the value 0xFF in any field to keep the value already in the real-time clock. Application: External clock can via RCI synchronize AlphaCom’s HH:MM setting once per day without changing the other fields.
Response: SYSTEM_TIME