Actions

Special

Search results

  • FLIR's Latitude Network Video Management System (NVMS) is interfaced to the ICX system or AlphaCom based on the STENTOFON .NET SDK. ===ICX===
    4 KB (542 words) - 11:14, 19 November 2019
  • ...ilding management system from ela-soft GmbH. Integration between GEMOS and ICX or AlphaCom is via the ACDP Simple Link Layer protocol. The following parag ==ICX/AlphaCom Setup==
    2 KB (351 words) - 11:03, 19 November 2019
  • ...d the installation procedure available on Zenitel Wiki from the 3'rd party integration section. ...e Milestone XProtect AddToLogServerService used for both integrations with ICX-AlphaCom or IC-EDGE.
    697 bytes (92 words) - 10:18, 30 June 2022
  • ...ppVision can be integrated with the ICX system or the AlphaCom system. The integration is via OPC. ===ICX===
    3 KB (467 words) - 14:14, 19 November 2019
  • ...e AlphaCom system and AC2000 from CEM Systems (Tyco) is based on a special integration module which is available from CEM Systems. ...vides seamless bi-directional communication between CEM Systems AC2000 and ICX/AlphaCom intercom servers and workstations, as well as their respective int
    6 KB (902 words) - 10:52, 19 November 2019
  • ICX-AlphaCom and AlphaCom interfaces to the Total Recall range of voice recorde [[Category:3rd party integration]]
    569 bytes (78 words) - 05:28, 23 August 2021
  • ...s article only ICX will be refered to, but the information relates to both ICX and AlphaCom.<br> ...multaneously. The ports are named “OPC Server 1” and “OPC Server 2” in the ICX. The ports are assigned the port numbers 61112 and 61113 respectively.<br>
    6 KB (903 words) - 00:23, 6 November 2019
  • ...ded for debug and on-site trouble shooting of SIP communication between an ICX or AlphaCom, and a SIP device. ==ICX==
    2 KB (275 words) - 16:39, 6 November 2020
  • = CCURE 9000 ICX-AlphaCom integration = In an Enterprise configuration (MAS and SAS), the integration module attempts to retrieve the list of available actions from the MAS. Thi
    1 KB (150 words) - 08:16, 4 August 2020
  • ...stem. The integration is based on EDO and event handler programming in the ICX/AlphaCom. When used with the ICX System, the following license is required in the ICX in order to enable the EDO port: 1002602400 - ILI-IF Interface enabling
    4 KB (552 words) - 13:59, 19 November 2019
  • ...be integrated with the ICX-AlphaCom system or the AlphaCom XE system. The integration is using the EDO port. Digital Sentry has an ASCII string based alarm input option. ICX or AlphaCom can send matching strings out from one its EDO-ports on events
    4 KB (613 words) - 09:03, 18 August 2021
  • ...d Sipelia which provides an interface from its Security Center Software to ICX or AlphaCom and intercom stations in SIP-mode. ==ICX System ==
    2 KB (293 words) - 16:10, 24 June 2020
  • ...sections only the name ICX will be used when there is no confusion between ICX-AlphaCom and AlphaCom). ==PACOM Unison / ICX Demo System==
    7 KB (1,035 words) - 15:55, 31 May 2022
  • ===ICX=== ICX requires the presence of the appropriate API/OPC license.
    5 KB (834 words) - 12:57, 17 March 2022
  • ...ls P2000 can be integrated with the ICX system or the AlphaCom system. The integration is using the MPC Data Protocol. ...intercom history messages and alarms. The P2000 system interfaces with the ICX/AlphaCom system to establish audio communication links between any two or m
    5 KB (714 words) - 13:48, 19 November 2019
  • ...he hardware and configuration required to connect ASL PAVA system with the ICX-AlphaCom system using a [[TKIE-2]] kit. This integration will enable:
    7 KB (1,287 words) - 14:08, 3 June 2022
  • ...using the [[ESPA 4.4.4|ESPA 4.4.4 protocol]], and activate features in the ICX/AlphaCom. The following types of systems have been tested: * When used with the ICX System, the following license is required in the ICX in order to enable the ESPA444 protocol: 1002602400 - ILI-IF Interface enab
    3 KB (456 words) - 11:10, 19 November 2019
  • ...port. This device allows for the connection of 1 PSTN style telephone to ICX-AlphaCom, AlphaCom or IC-Edge platforms. ...e HT-801 with ICX-AlphaCom or AlphaCom, you require 1 SIP Station License (ICX:1002600700, AlphaCom:1009643001)<br>
    3 KB (487 words) - 05:32, 25 March 2022
  • ...ports. This device allows for the connection of 2 PSTN style telephone to ICX-AlphaCom, AlphaCom or IC-Edge platforms. ...ICX-AlphaCom or AlphaCom, you require 1 SIP Station License per FXS port (ICX:1002600700, AlphaCom:1009643001)<br>
    3 KB (496 words) - 13:45, 28 April 2022
  • The integration between ICX or AlphaCom and the Pro-Watch from Honeywell is via the MPC protocol. ...rial and IP data connections. AlphaCom also support both methods, while in ICX one must use an Ethernet to Serial Converter if serial data is needed.
    8 KB (1,324 words) - 13:57, 11 February 2022
  • ...ports. This device allows for the connection of 8 PSTN style telephone to ICX-AlphaCom, AlphaCom or IC-Edge platforms. ...ICX-AlphaCom or AlphaCom, you require 1 SIP Station License per FXS port (ICX:1002600700, AlphaCom:1009643001)<br>
    3 KB (517 words) - 05:33, 25 March 2022
  • SIP phones have various local set-up and configuration options. The level of integration will depend on the configuration available on the current phone model. === Basic Integration Level ===
    10 KB (1,522 words) - 11:26, 19 March 2021
  • * [[M100_and_AlphaCom_interfacing#Door_Opening|AlphaCom/M100 Integration - Door Opening]] [[Category: ICX-AlphaCom features]]
    1 KB (196 words) - 14:56, 6 July 2022
  • '''Compatibility: Turbine Video Plus intercom is compatible with Edge, SIP, ICX-AlphaCom and AlphaCom systems.''' ...n viewed in LenelS2 OnGuard, recommendation is to use RTSP H.264 for video integration instead.
    2 KB (331 words) - 05:06, 8 March 2022
  • ...ture which connects Keep with a locally deployed Zenitel system. Multiple ICX-AlphaCom exchanges can be combined and incorporated into Keep, providing an Through the use of Event Definitions and Alarm Actions, the integration can also be expanded to enable custom alarm and alert notifications which a
    14 KB (2,278 words) - 10:40, 17 June 2022
  • The usage of the External Generic Event can only be implemented in an ICX-Alphacom Intercom system as it requires that the controller can send text s *ICX-AlphaCom Setup
    6 KB (889 words) - 13:37, 3 June 2022
  • ...Schneider Access Expert with a locally deployed Zenitel system. Multiple ICX-AlphaCom exchanges can be combined and incorporated into Schneider Access E Through the use of Event Definitions and Alarm Actions, the integration can also be expanded to enable custom alarm and alert notifications which a
    15 KB (2,407 words) - 13:54, 17 January 2022
  • {{note|Note: This article relates to the integration between OnGuard and ICX-AlphaCom, or AlphaCom with software version 13.1.3.3 or newer. For older Al ...lphaCom XE platforms with OnGuard. OnGuard users will be able to configure ICX and AlphaCom XE as a communication platform from within OnGuard System Admi
    14 KB (2,158 words) - 13:50, 16 June 2022
  • The ICX and AlphaCom systems can be interfaced to American Dynamics victor. ...and event handler programming in the ICX/AlphaCom. On the victor side the integration is through the General Purpose Interface.
    9 KB (1,491 words) - 17:11, 18 November 2019
  • '''Compatibility: Turbine Video Plus intercom is compatible with Edge, SIP, ICX and AlphaCom systems.''' ...n viewed in LenelS2 OnGuard, recommendation is to use RTSP H.264 for video integration instead.
    5 KB (729 words) - 05:05, 8 March 2022
  • [[Image:Teams integration.png|right|600px|thumb|Integration Overview]] ...bes how you connect intercom audio calls to Microsoft Teams, by connecting ICX-Alphacom to the Microsoft Certified Audiocodes Mediant 800 SBC solution.
    12 KB (1,920 words) - 11:02, 28 June 2021
  • #REDIRECT [[Milestone XProtect - ICX-AlphaCom Integration (ONVIF & Plugin)]] The interface between AlphaCom, ICX and Milestone XProtect VMS is through an integration module which is available on the download page of Zenitel Wiki.
    18 KB (2,902 words) - 13:15, 22 June 2022
  • The Software House CCURE 9000 can be integrated with the ICX system or the AlphaCom system. The interface is based on a special integration module which is available from Software House.
    24 KB (3,799 words) - 08:43, 8 July 2022
  • Only points that are specific to this integration and to its connected intercom stations are described. * Auto discover devices in the Milestone XProtect VMS, ensuring easy integration.
    14 KB (2,182 words) - 14:02, 6 July 2022
  • This article describes how to program the AlphaCom and ICX Recording Interface when used with 3rd party recorders. ==ICX Licenses==
    10 KB (1,448 words) - 02:12, 29 July 2022
  • [[Category: ICX-AlphaCom features]] [[Category:AlphaCom - SIP Integration]]
    2 KB (274 words) - 14:11, 3 June 2022
  • #REDIRECT [[Milestone XProtect - IC-Edge Integration (ONVIF & Plugin)]] The interface between IC-EDGE and Milestone XProtect VMS is through an integration module which is available on the download page of Zenitel Wiki.
    12 KB (1,870 words) - 13:26, 22 June 2022
  • ...e setup of the GSM gateway MV-370 (Mobile VoIP) for communication with the ICX system or the AlphaCom. ...or AlphaCom to the GSM network, as well as from the GSM network in to the ICX/AlphaCom.
    12 KB (1,878 words) - 11:51, 12 July 2021
  • To have multiple zone selection and only audio line from ICX-system to the Vipedia system an IP-LCM is used. This article will describe When you call a group call number in the ICX-AlphaCom a relay on the IP-LCM is activated. This in turn will set up a fix
    9 KB (1,493 words) - 14:07, 3 June 2022
  • [[Category:AlphaCom - SIP Integration]] [[Category: ICX-AlphaCom Applications]]
    2 KB (274 words) - 11:28, 8 July 2022
  • ...etween AlphaCom, ICX and IC-EDGE and Genetec Security Center is through an integration module which is available on the download page of Zenitel Wiki. Only points which are specific to this integration and to it connected intercom stations are described.
    24 KB (3,823 words) - 19:52, 2 December 2021
  • Only points that are specific to this integration and to its connected intercom stations are described. * Auto discover devices in the Milestone XProtect VMS, ensuring easy integration.
    21 KB (3,403 words) - 14:01, 6 July 2022
  • For integration with Milestone, please see: * [[Milestone XProtect - ICX-AlphaCom Integration (ONVIF & Plugin)]]
    20 KB (2,915 words) - 13:24, 22 June 2022
  • '''Compatibility: Turbine Video Plus intercom is compatible with Edge, SIP, ICX and AlphaCom systems.''' When Sound Detection (supported in ICX-AlphaCom mode) is enabled and sound is detected, the station emulates the p
    4 KB (660 words) - 05:04, 8 March 2022
  • This article describes how to set up the '''Akuvox R29S''' to operate in a '''ICX''' or '''AlphaCom system'''. The Akuvox R29S can be used for audio only, or ...29S requires a [[Licenses#SIP_station_license|SIP Station license]] in the ICX-Alphacom server.
    11 KB (1,722 words) - 15:47, 19 February 2021
  • For integration with Milestone, please see: * [[Milestone XProtect - ICX-AlphaCom Integration (ONVIF & Plugin)]]
    23 KB (3,439 words) - 13:24, 22 June 2022
  • ===MTN-3503 Station in ICX-AlphaCom mode freezes if offline for more than 2 minutes.=== If a station in “ICX-AlphaCom mode” loses the communication to the server for more than 2 minu
    5 KB (724 words) - 15:50, 7 June 2022
  • Previous Release - [[ICX 1.0.3.X - Release Notes]] Next Release - [[ICX 1.2.3.X - Release Notes]]
    10 KB (1,462 words) - 05:09, 8 March 2022
  • ...Management System) is a multi-site security management platform, providing integration between access control, alarm monitoring, video surveillance, elevator, int ...S test system configuration. A description of how the integration with the ICX is established can be found in the document:
    10 KB (1,382 words) - 10:23, 20 May 2020
  • ...ere are several Call Requests at the same time, they will be queued in the ICX-AlphaCom and handled one by one. The macro [[%tin|%tin (Trunk In Use)]] is * ICX-AlphaCom: any
    5 KB (887 words) - 14:21, 31 May 2022
  • Enter the IP Address of your ICX-AlphaCom or AlphaCom server. [[Category:3rd party integration]]
    4 KB (591 words) - 02:20, 2 July 2021
  • ...aCom; only when there is a noticeable difference between ICX and AlphaCom, ICX will be referred to separately. The SDK name itself will remain VS-SDK for ...(if not all) aspects of what normally is expected from an integration with ICX. Users of the SDK are allowed to freely use parts of the sample source code
    21 KB (3,152 words) - 15:04, 31 March 2022
  • For integration with Milestone, please see: * [[Milestone XProtect - ICX-AlphaCom Integration (ONVIF & Plugin)]]
    15 KB (2,313 words) - 13:24, 22 June 2022
  • * The ICX-AlphaCom (and AlphaCom XE) supports up to 500 logical RCOs. {{note|"Device" is not supported in the ICX-AlphaCom server. Here you should always use "Station".}}
    8 KB (1,257 words) - 16:11, 2 June 2022
  • WinGuard is the PSIM software from Advancis. Integration between WinGuard and ICX or AlphaCom system is via the ACDP protocol ([[AlphaNet Data Protocol]]), u In the ICX System the following license is required in order to enable the ACDP protoc
    21 KB (3,279 words) - 20:04, 11 January 2021
  • For integration between LenelS2 OnGuard and the ICX or AlphaCom system, see [[LenelS2 OnGuard System|here]]. The Edge Controller does not require any licenses from Zenitel for integration with OnGuard.
    12 KB (1,878 words) - 13:55, 6 July 2022
  • The ICX or AlphaCom system communicate with AMAG Symmetry via the MPC-protocol. ...ad4185_2034ad7a48434da98f741615a02af20d.pdf The Symmetry™ Intercom Control Integration package]
    20 KB (3,283 words) - 02:11, 22 October 2020
  • ...licenses for the ICX-AlphaCom see this article: [[Licenses for ICX-500 and ICX-AlphaCom Core]] }} ...and shared numbering plans. The SIP license is [[:Category:AlphaCom - SIP Integration|tested and verified]] towards several SIP systems on the market.
    16 KB (2,326 words) - 16:42, 28 June 2022
  • ==ICX-AlphaCom System== ! colspan="2" style="background:#ffd400;" width="620" |'''ICX-AlphaCom System'''
    61 KB (8,223 words) - 09:40, 14 July 2022
  • ...io can be transmitted directly without delay, or it can be recorded by the ICX-AlphaCom and dispatched after having listened to the recording ([[recall]]) ...y set Automatic M-Key for calls from all stations. This is useful in some Integration methods.
    8 KB (1,320 words) - 13:43, 5 July 2022
  • * '''ICX-AlphaCom mode''': ''Advanced AlphaCom'' > ''Video Settings'' {{Note|SIP H264 Call settings are not available in ICX-Alphacom Mode}}
    13 KB (1,920 words) - 10:11, 27 July 2021
  • [[Category:3rd party integration]] [[Category:ICX-AlphaCom Applications]]
    6 KB (886 words) - 14:31, 31 May 2022
  • ...OnGuard System''' with the [[:Category:AlphaCom_XE|AlphaCom system]]. The integration is using the MPC Data Protocol. ...are version older than 13.1.3.3. For a description of the integration with ICX-AlphaCom or AlphaCom with software version 13.1.3.3 or newer, please refer
    24 KB (3,768 words) - 14:52, 15 September 2020
  • [[Category: ICX-AlphaCom Applications]] [[Category:AlphaCom - SIP Integration]]
    13 KB (1,980 words) - 15:13, 31 May 2022
  • * ICX-AlphaCom: any When the operator picks up the call, the ICX-AlphaCom raises event 08.
    15 KB (2,369 words) - 14:09, 31 May 2022
  • [[Category:AlphaCom - SIP Integration]] [[Category: ICX-AlphaCom Applications]]
    9 KB (1,393 words) - 15:23, 31 May 2022
  • [[Category: ICX-AlphaCom Applications]] [[Category:3rd party integration]]
    8 KB (1,268 words) - 15:59, 31 May 2022
  • ...col for easy interoperability with telephone systems. Via SIP Trunking the ICX/AlphaCom can be interfaced to: [[File:SIPTrunking.PNG|thumb|500px|SIP Trunking with ICX or AlphaCom XE]]
    34 KB (5,440 words) - 13:40, 23 June 2022
  • ===MTN-3018 Added Multi-Webuser Support to Alphacom and ICX-Alphacom=== Exigo integration: Issues with setting up a call with high priority from AlphaCom to Exigo.
    22 KB (3,177 words) - 13:35, 28 June 2022
  • ...will carry on anyway. Maximum SIP users in a group call: 200 SIP users in ICX system, 50 SIP users in an AlphaCom system. {{note|In ICX-500 and ICX-AlphaCom Core the license "''[[Licenses_for_ICX-500_and_ICX-AlphaCom_Core|1
    67 KB (10,525 words) - 14:57, 6 July 2022
  • Provides a way of transferring value and string parameters from ICX or AlphaCom to VS-Operator. ...re more software integrations then available OPC/API ports; Note that each integration software must support the use of the AlphaNet Service Provider. Also see [[
    17 KB (2,702 words) - 14:20, 15 April 2021
  • ...e]] or a busy station, and the ringing tone or busy tone from the AlphaCom/ICX will be heard. This also makes it possible to use override features, such a ...[[EBMDR-8|Expansion Module EBMDR-8]]. See [[Turbine Inputs and Outputs in ICX-AlphaCom]] for more details.
    46 KB (7,292 words) - 09:59, 27 April 2022

View (previous 100 | next 100) (20 | 50 | 100 | 250 | 500)