Actions

Difference between revisions of "TCAS Connections"

From Zenitel Wiki

(Second Call Button)
 
(3 intermediate revisions by the same user not shown)
Line 9: Line 9:
 
* 0.9 mm wires: 4.0 km
 
* 0.9 mm wires: 4.0 km
  
The station line is connected to the station by means of an RJ45 connector at the rear side of the station, or optional by using the plugable screw connector.
+
The station line can be connected in to ways: 
 +
* By means of an RJ45 connector at the rear side of the station, or
 +
* By using the plugable screw connector
  
 +
Connection using the RJ45 connector:
 
[[File:WiringAnalogTCAS.png|thumb|left|800px]]
 
[[File:WiringAnalogTCAS.png|thumb|left|800px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
Line 20: Line 23:
 
<br>
 
<br>
  
== Second Call Key ==
+
== Second Call Button ==
The station is prepared for a future second call key (DAK2).
+
The station is prepared for a second external call button (DAK 2). The button can be connected between the A-wire and the lower leg on D6 on the print (highlighted in the image above).  
 
 
This second call key can be found on the print if wanted and utilized with an external call button.
 
 
[[File:TCAS Connections 2.PNG|thumb|left|500px]]
 
[[File:TCAS Connections 2.PNG|thumb|left|500px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
* A second external call key must be connected between the A-wire and the lower leg on D6 (highlighted in the image above).
 
  
 
[[Category: Turbine Connections]]
 
[[Category: Turbine Connections]]

Latest revision as of 12:51, 31 August 2018

AlphaCom icon 300px.png
TCAS substation - Rear side

This article describes connection details of the analog intercoms TCAS-1, TCAS-2 and TCAS-3.

Wiring

The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:

  • 0.5 mm wires: 1.4 km
  • 0.6 mm wires: 2.0 km
  • 0.9 mm wires: 4.0 km

The station line can be connected in to ways:

  • By means of an RJ45 connector at the rear side of the station, or
  • By using the plugable screw connector

Connection using the RJ45 connector:

WiringAnalogTCAS.png


Note icon The station cable is not a 1:1 cable!


For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board


Second Call Button

The station is prepared for a second external call button (DAK 2). The button can be connected between the A-wire and the lower leg on D6 on the print (highlighted in the image above).

TCAS Connections 2.PNG