Actions

TCAS Connections

From Zenitel Wiki

Revision as of 13:30, 16 August 2018 by Asle (talk | contribs)
AlphaCom icon 300px.png
TCAS substation - Rear side

This article describes connection details of the analog intercoms TCAS-1, TCAS-2 and TCAS-3.

Wiring

The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:

  • 0.5 mm wires: 1.4 km
  • 0.6 mm wires: 2.0 km
  • 0.9 mm wires: 4.0 km

The station line is connected to the station by means of an RJ45 connector, or optional by using the plugable screw connector.

WiringAnalogTCAS.png


Note icon The station cable is not a 1:1 cable!


For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board


Second Call Key

The station is prepared for a future second call key (DAK2).

This second call key can be found on the print if wanted and utilized with an external call button.

TCAS Connections 2.PNG


  • A second external call key must be connected between the A-wire and the lower leg on D6 (highlighted in the image above).