Actions

TCAS Dimensions & Mounting Instructions

From Zenitel Wiki

Revision as of 11:37, 9 October 2012 by Roarl (talk) (TCAS Compact Station Onwall Surface Mounting)
TCAS Dimmensions-1.PNG
  Dimensions (WxHxD) Weight Partnumber
TCAS1 180 x 120 x 54 mm 0.8 kg 1008114010
TCAS1 after flushmount 180 x 120 x 20 mm - -
TCAS1 with onwall box 180 x 120 x 82 mm - -
TCAS2 180 x 120 x 54 mm 1.0 kg 1008114020
TCAS2 after flushmount 180 x 120 x 20 mm - -
TCAS2 with onwall box 180 x 120 x 82 mm - -
TCAS3 180 x 120 x 54 mm 0.8 kg 1008114030
TCAS3 after flushmount 180 x 120 x 20 mm - -
TCAS3 with onwall box 180 x 120 x 82 mm - -


TCAS Compact Station Dimensions

TCAS Compact Station - Front view TCAS Compact Station - Side view


Onwall Surface Mounting

On-Wall Surface Mount Back Box - TA-1

Mounting holes are to be drilled as shown.

Max. recommended screw diameter: ISO M6 or ANSI 1/4". Screw length must be greater than 25 mm or 1". A4 stainless steel socket head screws/bolts are recommended. Max. recommended screw head diameter: 9.5 mm or 3/8".

Optional nylon washers for extra protection against corrosive effects between surfaces are provided. They should be placed at the bottom of the mounting holes. Grommets and an M20 cable gland are provided.

Onwall backbox Mounting holes - Side view Onwall backbox - Side view


On-Wall Surface Mounting Procedure

Onwall mounting - exploded view

1. Mount the back box onto the wall
2. Fit the gasket onto the back box with the ridged side facing down
–Plug the AlphaCom cable into the RJ-45 port on the station
3. Mount the Turbine station onto the back box with the M5 fasteners provided
Note! Use the grommets and M20 cable gland provided for the cable holes on the back box

Flush Mounting