Actions

Difference between revisions of "TCIS Indication LEDs"

From Zenitel Wiki

(LEDs on Front Plate)
(Status LEDs on PCB)
Line 28: Line 28:
  
 
=Status LEDs on PCB=
 
=Status LEDs on PCB=
 +
[[File:TCIS Indications 4.PNG|thumb|700px]]
 
'''<u>Flashing 2 red + 1 green</u>'''
 
'''<u>Flashing 2 red + 1 green</u>'''
 
:- Station has no connection to the AlphaCom server/exchange.
 
:- Station has no connection to the AlphaCom server/exchange.

Revision as of 15:29, 9 October 2012

LEDs on Front Plate

TCIS Indications 1.PNG

Status LEDs

- Bell icon lights yellow when a call is placed and ringing
- Talk icon lights green when a call is active and in conversation
- Door icon lights red when the door is unlocked or relay is active


TCIS Indications 2.PNG

Talk Icon: Flashing at 1 second intervals

- Station has no connection to the AlphaCom server/exchange.
Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom XE IP address configured
- Invalid IP address
- No gateway or wrong gateway to the AlphaCom server/exchange


TCIS Indications 3.PNG

Talk Icon: Flashing at 5 second intervals

- Station connected but NOT registered in the AlphaCom server/exchange.
Reason:
- Station has not been programmed in AlphaPro


Status LEDs on PCB

TCIS Indications 4.PNG

Flashing 2 red + 1 green

- Station has no connection to the AlphaCom server/exchange.

Flashing 1 red + 2 green

- Station connected but NOT registered in the AlphaCom server/exchange.

Flashing 3 green

- Station connected and registered in the AlphaCom server/exchange.


Ethernet Activity & Speed LEDs on PCB

TCIS Indications 5.PNG

Green LED

- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection

Yellow LED

- Steady light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection