Actions

Difference between revisions of "TCIS Indication LEDs"

From Zenitel Wiki

(LEDs on Front Plate)
(LEDs on Front Plate)
Line 10: Line 10:
  
 
'''Talk Icon: Flashing at 1 second intervals'''
 
'''Talk Icon: Flashing at 1 second intervals'''
:- Station has no connection to the AlphaCom server/exchange.
+
Station has no connection to the AlphaCom server/exchange.
::'''Possible reasons:'''
+
 
::- No connection to Ethernet  
+
Possible reasons:
::- Wrong AlphaCom XE IP address configured  
+
* No connection to Ethernet  
::- Invalid IP address  
+
* Wrong AlphaCom XE IP address configured  
::- No gateway or wrong gateway to the AlphaCom server/exchange  
+
* Invalid IP address  
 +
* No gateway or wrong gateway to the AlphaCom server/exchange
 +
 
 
[[File:TCIS Indications 2.PNG|thumb|100px|left]]
 
[[File:TCIS Indications 2.PNG|thumb|100px|left]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
Line 21: Line 23:
  
 
'''Talk Icon: Flashing at 5 second intervals'''
 
'''Talk Icon: Flashing at 5 second intervals'''
:- Station connected but NOT registered in the AlphaCom server/exchange.  
+
Station connected but NOT registered in the AlphaCom server/exchange.  
::'''Reason''':  
+
Reason:
::- Station has not been programmed in AlphaPro
+
* Station has not been programmed in AlphaPro
 +
 
 
[[File:TCIS Indications 3.PNG|thumb|100px|left]]
 
[[File:TCIS Indications 3.PNG|thumb|100px|left]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />

Revision as of 13:42, 12 October 2016

LEDs on Front Plate

Status LEDs

- Bell icon lights yellow when a call is placed and ringing
- Talk icon lights green when a call is active and in conversation
- Door icon lights red when the door is unlocked or relay is active
TCIS Indications 1.PNG



Talk Icon: Flashing at 1 second intervals Station has no connection to the AlphaCom server/exchange.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom XE IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the AlphaCom server/exchange
TCIS Indications 2.PNG



Talk Icon: Flashing at 5 second intervals Station connected but NOT registered in the AlphaCom server/exchange. Reason:

  • Station has not been programmed in AlphaPro
TCIS Indications 3.PNG


Status LEDs on PCB

TCIS Board Indications 1.png


Flashing 2 red + 1 green

- Station has no connection to the AlphaCom server.

Flashing 1 red + 2 green

- Station connected but NOT registered in the AlphaCom server.

Flashing 3 green

- Station connected and registered in the AlphaCom server.

Ethernet Activity & Speed LEDs on PCB

TCIS Board Indications 2.png


Green LED

- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection

Yellow LED

- Steady light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection