Actions

Difference between revisions of "TCIS Restore Factory Defaults"

From Zenitel Wiki

(Reset to Factory Default - IP address from DHCP)
(Reset to Factory Default - Static IP)
 
Line 27: Line 27:
  
 
==Reset to Factory Default - Static IP==
 
==Reset to Factory Default - Static IP==
<div style="text-align:left;"> <youtube width="300" height="180">HAt7Rt2AADE</youtube>  </div>
 
 
 
During the factory Default procedure the station will count numbers in its loudspeaker.
 
During the factory Default procedure the station will count numbers in its loudspeaker.
  

Latest revision as of 12:22, 24 October 2023

AEIPS.png

A Zenitel IP Station may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.


Reset to Factory Default - IP address from DHCP



During the factory Default procedure the station will count numbers in its loudspeaker.

  1. Press and hold any button, then power up the station.
  2. At the count 1, release the button
  3. At the count 5 press and hold the button.
  4. At the count 0 release the button. If there is no 0 count, the procedure has failed and you have to start again


After the station has started up, press the call button, and the station will speak its IP address

Factory Default with IP address from DHCP server


Factory default values

  • Station IP address: Obtained from a DHCP server. If no DHCP server is available, it gets a random 169.254.x.x address.
  • Username: admin
  • Password: alphaadmin
  • Mode of operation: Edge

Reset to Factory Default - Static IP

During the factory Default procedure the station will count numbers in its loudspeaker.

  1. Press and hold any button, then power up the station.
  2. At the count 1, release the button
  3. At the count 3 press and hold the button.
  4. At the count 0 release the button. If there is no 0 count, the procedure has failed and you have to start again


After the station has started up, press the call button, and the station will speak its IP address

Factory Default with Static IP Address


Factory default values

  • Station IP address: 169.254.1.100
  • Username: admin
  • Password: alphaadmin
  • Mode of operation: Edge