Actions

Difference between revisions of "TCIx Connections"

From Zenitel Wiki

Line 1: Line 1:
 
{{APS}}
 
{{APS}}
 +
===Network Connection===
 +
Connect your Intercom station to the data network
 +
[[File:TCIS-X top.PNG|thumb|left|250px|Turbine Compact top view]]
 +
<br style="clear:both;" />
 +
There is one RJ-45 port located on the Turbine Compact station that is used for PoE/LAN Ethernet connection.
 +
 
=== External Connectors ===
 
=== External Connectors ===
 
[[File:TCIS Connections 1.PNG|right|350px|thumb|External Connectors on Turbine IP Station]]
 
[[File:TCIS Connections 1.PNG|right|350px|thumb|External Connectors on Turbine IP Station]]
Line 15: Line 21:
  
 
If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply.
 
If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply.
 
===Network Connection===
 
[[File:TCIS-X top.PNG|thumb|left|250px|Turbine Compact top view]]
 
<br style="clear:both;" />
 
There is one RJ-45 port located on the Turbine Compact station that is used for PoE/LAN Ethernet connection.
 
  
 
===Input/Output Connections===
 
===Input/Output Connections===

Revision as of 18:46, 13 March 2017

APS.png

Network Connection

Connect your Intercom station to the data network

Turbine Compact top view


There is one RJ-45 port located on the Turbine Compact station that is used for PoE/LAN Ethernet connection.

External Connectors

External Connectors on Turbine IP Station
TCIS-X rear.PNG


  • Ethernet/Power: 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
  • Secondary Power: 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
  • Relays: There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
  • Input/Output: 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
  • Audio Line Out: A balanced 600 ohm audio line out with induction loop signal

Power Supply

The Turbine Compact Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.

If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply.

Input/Output Connections

There are 6 I/O connection options for the Turbine Compact Station. These connections are used as relay contacts for door lock control and external I/O devices.

For more details see Turbine Compact Board Connectors