TFIX - Installation Solutions

From Zenitel Wiki

TFIX station with external signal device

In noisy areas a beacon lamp and/or a signal bell/horn can be used to indicate an incoming call or PA announcement.

Single TFIX with external signal device

A single TFIX with external signal device in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:

  • 1 Turbine extended kit; TKIE
  • 1 Turbine Relay board; TA-10
  • 1 24VDC or 230VAC PSU for signal device
  • 1 Flowire unit; FCDC2
  • 1 24VDC Flowire PSU
TFIX Beacon Single.png


Detailed connection diagram


Multiple TFIX'es with external signal device

Multiple TFIX'es with external signal device in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field.
Each cabinet consist of:

  • 1 Turbine extended kit; TKIE
  • 1 Turbine Relay board; TA-10
  • 1 24VDC or 230VAC PSU for external signal device
  • 1 Flowire unit; FCDC2
  • 1 24VDC Flowire PSU
TFIX Beacon Multiple2.png



Multiple TFIX'es with external signal device in the EX zone, where all controlling equipment is located in the server room.
For every sixth TFIX with beacon you need:

  • 1 Turbine compact Kit; TKIS-2
  • 1 Multi-relay board; MRBD
  • 1 24VDC PSU: for the MRBD
  • 1 Flowire unit; FCDC2
  • 1 24VDC Flowire PSU
  • 6 Relay boxes; IRR-3
  • 6 External signal devices; Beacon BEX24O/BEX230O, or Signal bell/horn DHW2-24/DHH1-230
  • 6 24VDC or 230VAC PSU for external signal device
TFIX Beacon Multiple1.png


Detailed connection diagram