Actions

Difference between revisions of "TFIX Restore Factory Defaults"

From Zenitel Wiki

(Factory default values)
Line 1: Line 1:
 
A Turbine EX Station may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.
 
A Turbine EX Station may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.
 
   
 
   
NOTE! A TFIX Factory Default will also reset the Flowire NMK password. See [[Flowire_clusters#Setting_the_NMK_in_an_installation_with_TFIX_stations|here for more]]
+
{{note|Factory Default of the TFIX station will also reset the Flowire NMK password. See [[Flowire_clusters#Setting_the_NMK_in_an_installation_with_TFIX_stations|here for more]]}}
  
 
= Reset to Factory Default Settings with Activated DHCP =
 
= Reset to Factory Default Settings with Activated DHCP =

Revision as of 11:35, 8 November 2019

A Turbine EX Station may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.

Note icon Factory Default of the TFIX station will also reset the Flowire NMK password. See here for more


Reset to Factory Default Settings with Activated DHCP

Factory Default with IP address from DHCP server



To reset:

1. While pressing any button, power up the station.
2. Hold the button until the station audio starts counting, and release the button on count 1.
3. Press and hold the button on count 5 and release on count 0.
- if there is no 0 count, the procedure has failed and you have to start again
4. Press the call button to make the station say its IP address.

Factory default values

Station IP address: Determined by DHCP server. If no DHCP server is available, it gets a random 169.254.x.x address.
Username: admin
Password: alphaadmin


Reset to Factory Default Settings with Static IP

Factory Default with Static IP Address


To reset:

1. While pressing any button, power up the station.
2. Hold the button until the station audio starts counting, and release the button on count 1.
3. Press and hold the button on count 3 and release on count 0.
- if there is no 0 count, the procedure has failed and you have to start again
4. Press the call button to make the station say its IP address.

Factory default values

Station IP address: 169.254.1.100
Username: admin
Password: alphaadmin