Actions

TMIS Indication LEDs

From Zenitel Wiki

Revision as of 13:15, 17 November 2020 by Roarl (talk | contribs)

LEDs on Front Plate

Status LEDs

- Talk icon LED lights amber when a call is active and in conversation
- Door icon LED lights green when the door is unlocked or relay is active
TMIS-1 LED icon1.PNG



Call button LED: Flashing at 1 second intervals Station has no connection to the AlphaCom server/exchange.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom XE IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the AlphaCom server/exchange
TMIS-1 LED icon2.PNG



Call button LED: Flashing at 5 second intervals Station connected but NOT registered in the AlphaCom server/exchange.

Reason:

  • Station has not been programmed in AlphaPro
TCIS Indications 3.PNG


Status LEDs on PCB

TCIS Board Indications 1.png


Flashing 2 red + 1 green

  • Station has no connection to the AlphaCom server.

Flashing 1 red + 2 green

  • Station connected but NOT registered in the AlphaCom server.

Flashing 3 green

  • Station connected and registered in the AlphaCom server.

Ethernet Activity & Speed LEDs on PCB

TCIS Board Indications 2.png


Green LED

  • Steady light: Ethernet connection OK
  • Flashing: Ethernet data traffic
  • No light: No Ethernet connection

Yellow LED

  • Steady light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection