Actions

Difference between revisions of "Tamper and Vandal Proof Station - 1007063000"

From Zenitel Wiki

(Description)
 
(21 intermediate revisions by 2 users not shown)
Line 1: Line 1:
[[Image:Tamper and Vandal Proof Station 100 7063 000.jpg|thumb|250px|100 7063 000 station]]
+
{{A}}
 +
[[Image:1007063000.PNG|thumb|200px|100 7063 000 station]]
 +
The '''Tamper and Vandal Proof Station - 1007063000''' is an analog intercom station. It is connected to an [[ASLT|ASLT line card]] in an [[AlphaCom XE7]], [[AlphaCom XE20]] or [[AlphaCom XE26]] server using 2 pairs of wires.
  
== Features ==
+
==Highlights==
 
* Analogue intercom station specially designed for prison and correctional facilities
 
* Analogue intercom station specially designed for prison and correctional facilities
 
* Advanced safety solution including scream, assault and tamper alarms
 
* Advanced safety solution including scream, assault and tamper alarms
Line 11: Line 13:
 
* Redundant backup for power and signaling
 
* Redundant backup for power and signaling
  
== Description ==
+
<br>
The Tamper and Vandal Proof station type 1007063000 is
 
designed specially for prisons and correctional facilities with
 
safety and security for both guards and prisoners in mind.
 
  
The station is much more than a traditional intercom for prison
+
== Connections and configuration ==
cells. The station comes with inbuilt scream alarm, assault
+
[[image:Tamper and Vandal Proof Station 100 7061 000 Installation.jpg|thumb|left|500px|Installation overview]]
alarm, light signaling, external controls, entertainment functions
+
<br style="clear:both;" />
and cell light switch.
 
  
The front plate is in 2,5 mm stainless steel and equipped with 5
+
* [[PrisCom Station Connections]]
vandal proof sensor buttons. If the prisoner in some way should
+
* [[PrisCom station - Configuration|PrisCom station Configuration]]
manage to open the station, a tamper alarm will be triggered.
 
If the station is disconnected, or the wires to the station are
 
shorted, a request for action will be generated.
 
  
Call request form the cell, guard presence and alarm calls are
+
{{note|The station should not be exposed to humid environment or water drops. Due to the way in which sensor keys operate, the Vandal and Tamper Proof Stations 1007061000 and 1007063000 do not always work reliably when these stations are put into a humid or wet environment. See the description of [[Set of sensor keys - 1007060110|Sensor Keys]] for more details. }}
indicated on the guard’s intercom station as well as by signal
 
lamps outside the cell and in the guard room.
 
  
The station works in a dual redundant mode. If the link to the
+
==Related Articles==
intercom exchange fails, the lamp signaling will still work. If the
+
* [http://www.zenitel.com/product/tamper-and-vandal-proof-station Additional Documentation on Zenitel.com]
lamp signaling fails, all intercom signaling will remain intact.
+
* [[Corridor Lamp - 1007060130]]
 
+
* [[Remote call button - 1007060120]]
The sensitivity of the vandal proof sensor buttons can be set to
+
* [[Set of sensor keys - 1007060110]]
‘normal’ or ‘high’, where the latter is intended for use by guards
+
* [[Back box on wall mount - 1007060150]]
wearing rubber gloves. In order to keep the sensitivity at the
+
* [[Back box flush mount - 1007060155]]
correct level, the stations must be installed in a dry, indoor
 
location.
 
 
 
For cleaning purposes, the station is protected to IP65; fluid
 
will not harm the station, but operation is only optimal when the
 
surface is dry again.
 
  
== Specifications ==
 
{|
 
|width="150px"|Dimensions: (WxHxD)
 
|128 x 264 x 51 mm, 5.0 x 10.4 x 2.4 in
 
|-
 
|Weight || 950 g, 2.1 lb
 
|-
 
|Finish || 2.5 mm brushed stainless steel
 
|-
 
|Mounting || Flush in back box, 6 tamper proof screws
 
|-
 
|Button || Vandal proof sensor type
 
|-
 
|Gen. purp. I/O ports || 3 x input - contact closure, 2 x output - 24VDC/1A
 
|-
 
|Lamp outputs || Call - present - tamper - group
 
|-
 
|Lamp drivers || 24VDC/1A overload protected
 
|-
 
|Operating Voltage || 24 (11-27) VDC
 
|-
 
|Cable Requirements || 2 pair twisted cable, 0.5-0.6 mm / 24 AWG
 
|-
 
|Temperature || -40 C to +55 C
 
|-
 
|Relative humidity || 0% - 95%
 
|-
 
|Loudspeaker Output || 1 W RMS
 
|-
 
|Frequency Range || 200 - 10000 Hz
 
|-
 
|Back-box type || LBB 7076/76
 
|-
 
|}
 
  
== Installation ==
 
[[image:Tamper and Vandal Proof Station 100 7063 000 Installation.jpg|thumb|left|250px|]]<br>
 
<br>
 
<br>
 
<br>
 
<br>
 
<br>
 
<br>
 
<br>
 
  
== Flush Mount Back Box With Anchors ==
 
[[image:Tamper and Vandal Proof Station 100 7063 000 Flush mount back box.jpg|thumb|left|250px]]
 
[[Image:890070737601.PNG|thumb|right|250px]]
 
  
<br style="clear:both;" />
 
  
==Related Articles==
 
* [[Back box on wall mount - 1007060150]]
 
  
[[Category: Stations]]
+
[[Category: Analogue 4-wire Stations]]
[[Category: Vandal Resistant Stations]]
 

Latest revision as of 22:49, 30 October 2018

AlphaCom icon 300px.png
100 7063 000 station

The Tamper and Vandal Proof Station - 1007063000 is an analog intercom station. It is connected to an ASLT line card in an AlphaCom XE7, AlphaCom XE20 or AlphaCom XE26 server using 2 pairs of wires.

Highlights

  • Analogue intercom station specially designed for prison and correctional facilities
  • Advanced safety solution including scream, assault and tamper alarms
  • Vandal proof design with 2.5 mm steel front, sensor buttons, microphone/speaker protection and water resistant
  • Music distribution with volume control
  • Integrated light signaling system
  • Integrated cell light button and switch
  • Programmable I/O ports for controlling door status, lamps, TV sets, sensors and more
  • Redundant backup for power and signaling


Connections and configuration

Installation overview


Note icon The station should not be exposed to humid environment or water drops. Due to the way in which sensor keys operate, the Vandal and Tamper Proof Stations 1007061000 and 1007063000 do not always work reliably when these stations are put into a humid or wet environment. See the description of Sensor Keys for more details.