Actions

TouchLine Key Signaling

From Zenitel Wiki

Revision as of 12:25, 10 May 2007 by Asle (talk) (Optional DAK Acknowledge)

Signalig protocol

To types of signaling protocols used towards the stations, Current Signaling and Tone Signaling

Current Signaling

Digit Signaling

Station keyboard digits 0 - 9 use sinewave tones in the range 500Hz to 2300 Hz, at 200 Hz steps.

  • Digit 0: 500 Hz
  • Digit 1: 700 Hz
  • Digit 2: 900 Hz
  • Digit 3: 1100 Hz
  • Digit 4: 1300 Hz
  • Digit 5: 1500 Hz
  • Digit 6: 1700 Hz
  • Digit 7: 1900 Hz
  • Digit 8: 2100 Hz
  • Digit 9: 2300 Hz

Extended Digit Signaling

In addition to the keyboard digits 0 - 9 another set of 10 tones are used for DAK signaling for CRM IV, Dual Display and PrisCom stations.

These tones 10-19 are sinewave tones in the range 600Hz to 2400 Hz, at 200 Hz steps.

DAK Signaling

Master stations use a combination of current signaling (M) and digits:

  • DAK 1: M + digit 0
  • DAK 2: M + digit 1
  • DAK 3: M + digit 2
  • DAK 4: M + digit 3
  • DAK 5: M + digit 4
  • DAK 6: M + digit 5
  • DAK 7: M + digit 6
  • DAK 8: M + digit 7
  • DAK 9: M + digit 8
  • DAK 10: M + digit 9


CRM IV and Dual Display Stations also use a combination of current signaling and digits:

  • D1-D10: M+0 - M+9
  • D11-D20: digit 10-19
  • D21-D30: M+10 - M+19
  • D31-D40: C+0 - C+9
  • D41-D50: C+10 - C+19
  • D51-D60: (Prefix +) M+0 - M+9
  • D61-D70: (Prefix +) digit 10-19
  • D71-D80: (Prefix +) M+10 - M+19
  • D81-D90: (Prefix +) C+0 - C+9
  • D91-D100: (Prefix +) C+10 - C+19

Prefix = ID+C


Priscom Stations uses so called Two Tone signaling which is a combination of Extended Digit Signaling and Digit Signaling:

  • Key board digit 0-9
    • Digit Tone 0-9
  • DAK D1-D15
    • Digit tone 10 + 0 to 10 + 14
  • DAK D16-D30
    • Digit tone 11 + 0 to 11 + 14
  • DAK D31-D45
    • Digit tone 12 + 0 to 12 + 14
  • DAK D46-D60
    • Digit tone 13 + 0 to 13 + 14
  • DAK D61-D75
    • Digit tone 14 + 0 to 14 + 14
  • DAK D76-D90
    • Digit tone 15 + 0 to 15 + 14
  • DAK D91-D100
    • Digit tone 16 + 0 to 16 + 9


Substations use current signaling only:

  • DAK 1: ID
  • DAK 2: ID + M
  • DAK 3 ID + LT

Optional DAK Acknowledge

A station using Two Tone Signaling can be configured with acknowledge on DAK keys:

  • The AMC application will send an acknowledge message by the Display Text Protocol.
  • The station will acknowled this by sending tone 18.