Actions

Difference between revisions of "Touchless sensor (w/ backbox)"

From Zenitel Wiki

(Configuration on IC-Edge)
(Configuration on IC-Edge)
Line 37: Line 37:
 
[[File:Direct Access Keys.png|thumb|500px|left|Direct Access Keys]]
 
[[File:Direct Access Keys.png|thumb|500px|left|Direct Access Keys]]
 
<br style="clear:both;" />  
 
<br style="clear:both;" />  
 +
 
Inputs (and DAK keys) have two states:
 
Inputs (and DAK keys) have two states:
 
* '''Idle''':  There is no active call on the station.
 
* '''Idle''':  There is no active call on the station.
 
* '''Call''': There is an incoming, outgoing or active call on the station.
 
* '''Call''': There is an incoming, outgoing or active call on the station.
 +
=== From Idle ===
 +
From '''IDLE''' state the following options are available (note that the available options will depend on the station type):
 +
 +
* '''Call To''': Enter the directory number to call when the DAK key/Input is pressed. Extended call options (parallel ringing, call escalation, etc.)
  
 
[[Category:Additional equipment]]
 
[[Category:Additional equipment]]

Revision as of 12:45, 20 October 2020

Touchless sensor, item 2390020100

The Touchless sensor (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button.

Highlights

  • Input Voltage: 5V
  • Available contacts: Normally Open & Normally Closed
  • Operating distance 3 to 20 cm (adjustable)
  • IP 66

Connections

Connections are made to the switch using the supplied 5 pin plug.
Correct orientation of the plug is ensured by the connector locating guides.

Color code

  • Red - +5 Volt supply
  • Brown - 0 Volt supply
  • Green - Normally Closed
  • Blue - Common
  • Purple - Normally Open

Settings

Touchless sensor - back


Typical Application

Touchless sensor - general wiring


Use Case Examples

Touchless sensor wired to Input 1 on a Turbine station:

Touchless sensor - wiring example


Configuration on IC-Edge

To configure the Inputs select Edge Controller > System Configuration > Direct Access Keys.
Select Show/Hide Settings on the station you want to configure:

Direct Access Keys


Inputs (and DAK keys) have two states:

  • Idle: There is no active call on the station.
  • Call: There is an incoming, outgoing or active call on the station.

From Idle

From IDLE state the following options are available (note that the available options will depend on the station type):

  • Call To: Enter the directory number to call when the DAK key/Input is pressed. Extended call options (parallel ringing, call escalation, etc.)