Actions

Difference between revisions of "Turbine 6.1 - Release notes"

From Zenitel Wiki

(Fixed issues - Exigo Amplifiers)
(MTN-1466 Cannot save firewall settings for same port with different protocols)
Line 120: Line 120:
 
=== MTN-1466 Cannot save firewall settings for same port with different protocols===  
 
=== MTN-1466 Cannot save firewall settings for same port with different protocols===  
 
It was not possible to save firewall settings if rules with the same port number but different protocols (for example port 5060 which has rules for tcp and udp) were edited. This is now fixed.
 
It was not possible to save firewall settings if rules with the same port number but different protocols (for example port 5060 which has rules for tcp and udp) were edited. This is now fixed.
 +
 +
<br>
  
 
== Fixed issues - Exigo Amplifiers ==
 
== Fixed issues - Exigo Amplifiers ==

Revision as of 15:52, 8 April 2021

Contents

Release info

This document provides the release notes for VSF-Turbine 6.1 with incremental bug fix releases. The release notes for VSF-Turbine 6.1 describe new features, improvements and issues fixed after VSF-Turbine 5.1.

Name: VSF-Turbine
Description: VSF-Turbine is a firmware archive for all Turbine Family Intercom stations including devices: TCIS-x, TCIV-x, TKIS-2, TMIS-x, TFIE-x, TKIE-x, TFIX-x, IP-LCM, ECPIR-3P, Exigo IP speakers. Exigo Network Amplifiers (only SIP mode and ICX- AlphaCom mode), and ENA-2060 (only in SIP mode) The firmware is delivered in a ZIP archive:.
Version:

  • vsft-6.1.x.x - Used for standard in-field upgrades

Date: 07.04.2021
Status: General Availability Compatibility: Pulse to IC-EDGE System
You can upgrade from Pulse (VS-IS 4.x) to IC-EDGE, but the whole system needs to run with the same Turbine software (VS-IS 5/6).
In an IC-EDGE System, INCA intercoms cannot be used as the Edge Controller.
TCIV video intercoms should not be used as the Edge Controller for systems exceeding 4 devices.
IMT 1.5 or newer can be used for station discovery and upgrade but must not be used to configure IC-EDGE.
Pulse to IC-EDGE Licenses
Pulse licenses will be honored in an IC-EGDE System. This means that when you upgrade firmware from VS-IS 4.x to 5.x/6.x your Pulse licenses will work for IC-EDGE.

Note icon The number of free VS station licenses has been increased from 16 to 32 in IC-EDGE. This means that you get an additional 16 VS stations to connect to in IC-EDGE


Note icon Both Multisite Trunking and VS-Client are free of charge in IC-EDGE


VSF-TURBINE 6.1.3.0

New Features - Turbine Intercom

MTN-3144 Third button option for hold state.

Added third button option under Direct Access Keys for managing calls that are put on hold. This option is available in SIP and Edge.

MTN-3114 Added functionality to force ringing on both accessory and internal loudspeaker

Force loudspeaker ringing option is available in call settings in all modes. It is disabled by default.

MTN-2956 Whitelist functionality is now added for SIP mode.

If whitelist is enabled on the station callers that are not added to whitelist are rejected.


Improvements - Turbine Intercom

TYR-109 Security hardening for TLS connections and Secure SIP

Security level set to 112 bits of security. As a result RSA, DSA and DH keys shorter than 2048 bits and ECC keys shorter than 224 bits are prohibited. Any ciphersuite using RC4 is also prohibited. SSL version 3 is also not allowed. Compression is disabled.

MTN-3093 Improved Tone test to combat noisy environment and to be able to use in places with multiple stations in the close vicinity

Tone volume is automatically adjusted to suit the ambient noise levels and therefore make it suitable to use it in noisy environment. Further improvement is made for environments like a train where multiple stations are next to each other. This might have caused the intercom with faulty speaker picks up tone from another station doing the test at the same time and wrongly reports success. This is now solved by playing multiple frequency tones.

MTN-2852 Frontboard DAK can now be configured to switch to internal speaker while performing PTT.

This is used as a workaround for issues with headset auto detect. User is able to configure DAK key to send M key as well as switch to internal speaker. This is exposed for TFIX and TFIE stations in call settings of ICX AlphaCom mode.

MTN-2770 SNMP now allows subnet 32 in allowed network

SNMP now allows subnet 32 in allowed network making possible to limit SNMP traffic to only one IP address.

MTN-2693 Added call monitoring options

In SIP mode it is possible to configure SIP OPTIONS timer to monitor established calls. If the remote part in a call is unavailable, the call will automatically be hung up. This option is available in advanced configuration mode. Changed registration handling

The minimum registration time is now 30 seconds. If registration time is configured to be below 60 seconds the registration will fail 15 seconds after initial registration message when the SIP server is not responding.

When station fails to register to a SIP server associated calls which are ringing or queued will now be automatically hung up.

MTN-2689 Additional information shown for uploaded certificates

Uploaded certificates will now show expiry date, issuer and subject.

MTN-2661 Options for adjusting CH1 and CH2 offset gain now visible on both normal and extended turbines.

MTN-1045 Disable scrolling while in call

Stations which have address book and scroll buttons are no longer able to use those buttons while there's an active, incoming or outgoing call.


Improvements - Exigo Amplifiers

MTN-2694 Support for revert logic handling on ENA 2060's dry contact input

External fault reporting can now be configured to reverse fault reporting logic. Additionally read IP address and disable factory reset are now exposed on station web for Exigo Network Amplifiers.


Fixed issues - Turbine Intercom

MTN-3231 Address book is not downloaded with .csv extension.

When you would download address book it would download as .txt. Now this is fixed.

MTN-3057 Group Calling in Sipelia

Video will now stream when Group Call in Sipelia is established.

MTN-2836 TFTP provisioning would sometimes look for wrong filename if SIP domain was not configured

TFTP provisioning would sometimes look for wrong file with IPv6 address instead of IPv4 address if the primary SIP domain was not configured. This has been fixed.

MTN-2824 Audio Messages - station offline message not played

Offline message would not be played, this has been fixed.

MTN-2823 Call is now terminated in exactly 40 seconds if other party is unavailable.

Before, detection period using the SIP OPTIONS, of other device going offline was random and up to several minutes based on device MAC.

MTN-2820 Mobile app crash during QR code scan

Bug fix for mobile app crash during QR code scan caused by empty item in Global Address list.

MTN-2814 Offset gain applied was applied wrong

Offset gain was applied wrong, causing it to be much higher than it should be

MTN-2795 Audio stops working

If the station detects audio issues, the audio driver will be reset. This might cause a 1 second drop in the audio.

MTN-2794 Edge controller parallel ringing ringlist configuration is now working correctly.

Before there was issue where saving buttons on a station over Edge controller would reset parallel ringing configuration used when calling ringlist for that particular station. Workaround was to save ringlist settings on Edge Controller again.

MTN-2777 Line out audio distorted when more than 6dB CH2 gain applied

When more than 6dB Volume CH2 (gain) was applied audio was distorted because gain jumped to 24dB regardless of value. Volume CH2 (gain) should now follow set value.

MTN-2774 Properly show values in Manual Time configuration

Values for Manual Time configuration are now properly shown and are not only partially visible.

MTN-2759 Missing pages in station web for ICX-Alphacom mode

Web configuration pages

  • Backup and restore
  • Logging

are now visible in ICX-Alphacom mode again.

MTN-2755 Mobile app loses registration after Edge Controller reboot

When Edge Controller is rebooted mobile app would lose registration after 10 minutes, if app was not active in that time frame. This has now been fixed.

MTN-2663 Video lost on TCIV in some rare cases

In some rare cases video can be lost on TCIV produced in 2019 and earlier. If this happens the TCIV needs to be replaced. This issue cannot occur if upgraded to latest software image.

MTN-1466 Cannot save firewall settings for same port with different protocols

It was not possible to save firewall settings if rules with the same port number but different protocols (for example port 5060 which has rules for tcp and udp) were edited. This is now fixed.


Fixed issues - Exigo Amplifiers

MTN-2972 SNMP daemon uses too much memory when SNMP traps are enabled

When SNMP traps (notifications) are enabled snmpd uses too much memory since it stores 1000 last traps with 24h timeout in log. This has been reduced to 10 traps with 1 hour timeout

MTN-2739 Amplifier Class D chip may crash when analog bypass is used

When analog bypass is used on ENA2200/ENA2400, audio filters were not active which could cause Class D chip to crash. Analog bypass is now changed to Digital (SW) bypass that applies audio filters

In Exigo Management Tool, the Amplifier output channel setting "HW Bypass Mode" on all ENA amplifier types is renamed to "Bypass Mode".

Also, the Bypass Mode can now be set individually for each Amplifier output channel on all ENA device types.


Known Issues

MTN-2692 Turbine stations won't register to ICX500 or Alphacom if the dash symbol is not removed from the Directory Number field

In an unconfigured Turbine station there is a dash character in the Directory Number field in the "Main Settings menu. This dash symbol must be removed when the directory number is entered, else the station will fail to register.

MTN-2686 Outputs not working for Exigo amplifiers in SIP mode

GPO's does not work when exigo amplifiers are in SIP mode.

MTN-2363 Factory reset does not delete uploaded Script

All uploaded scripts should also be removed on Factory reset.

MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream

H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.

MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR

RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream

MTN-2360 Client side forwarding does not work in SIP mode

Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.

MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer

Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki when adding TCIV station to Pelco

MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio

When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.

MTN-2356 SNMP not working properly on TCIV under high CPU load

SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.

MTN-2339 Group call chime is not played on 3rd party SIP stations

Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.