Actions

Difference between revisions of "Turbine Compact - Image recovery"

From Zenitel Wiki

(Requirements)
(The USB to Serial cable)
Line 16: Line 16:
  
  
=== The USB to Serial cable ===
+
=== Preparation of the USB to Serial cable ===
  
 
The Turbine station has a TTL level serial interface which we need to connect to during the upgrade process. For this purpose a USB to Serial converter cable can be used. Recommended cable is [http://uk.farnell.com/ftdi/ttl-232r-3v3/cable-usb-to-ttl-level-serial-conv/dp/1329311?Ntt=FTDI+-+TTL-232R-3V3+-+CABLE TTL-232R-3V3] from Farnell.  
 
The Turbine station has a TTL level serial interface which we need to connect to during the upgrade process. For this purpose a USB to Serial converter cable can be used. Recommended cable is [http://uk.farnell.com/ftdi/ttl-232r-3v3/cable-usb-to-ttl-level-serial-conv/dp/1329311?Ntt=FTDI+-+TTL-232R-3V3+-+CABLE TTL-232R-3V3] from Farnell.  

Revision as of 16:39, 17 December 2013

This article describes how the flash image of a Turbine Compact station can be recovered.

Before starting the upgrade process it is important to identify if the bootloader is corrupted or not.

  • Corrupted bootloader
  • The bootloader is intact

Requirements

  • The application "Turbine Station Production Upgrade Application" installed on a Windows PC.
  • A serial connection from the PC to the Turbine Compact board, using a USB to Serial cable
  • A terminal emulator program, PuTTY is recommended
Setup



Preparation of the USB to Serial cable

The Turbine station has a TTL level serial interface which we need to connect to during the upgrade process. For this purpose a USB to Serial converter cable can be used. Recommended cable is TTL-232R-3V3 from Farnell.

This cable needs to be slightly modified as per photo below:

  • Pin 1 = Black (GND)
  • Pin 2 = Orange (Turbine RX)
  • Pin 3 = Yellow (Turbine TX)
Original cable


Modified cable



Insert the USB connector in the PC. The unit will now install itself. Make a note of which COM port it becomes.


Cable connection to Turbine serial interface. Note the additional strap which is required