Actions

Turbine Software Upgrade

From Zenitel Wiki

Revision as of 16:39, 20 October 2015 by Asle (talk) (Upgrade Via AlphaCom XE)

This article describes how to upgrade the software in the Turbine Compact and Industri IP Stations.

There are two ways of upgrading the software on the IP station:

  • Uploading the software via the web interface of the station
  • Uploading the software via AlphaWeb on the AlphaCom server

Prerequisites

Both upgrade methods require that an TFTP Server is available and that the latest software image files have been downloaded from Downloads. During the upgrade process, the IP station will connect to the TFTP Server and download the software. Install the TFTP Server program on your PC. The TFTP Server can be downloaded from Downloads

Upgrade Via Station Web Interface

  • Start the TFTP server program and click Browse to select the folder where the software image files are located
TCIS Software Upgrade 1.PNG


1. Log on to the IP Station web interface
2. Select Station Administration> Manual Upgrade
TCIS Software Upgrade 2.PNG


3. Enter the IP address of the TFTP server(your PC’s IP address)
4. Enter the prefix (e.g. tsi-3.x.x.x)to the software image files in the Image file field
5. Click Save settings to store the data

The station will now try to contact the TFTP server. If the connection cannot be established or the tftp_test.txt file is missing from the folder, the message TFTP_CONN_ERROR is displayed. If the response is TFTP_CONN_OK the settings are saved, and the Upgrade button will appear.

TCIS Software Upgrade 3.PNG


  • Click the Upgradebutton to upgrade the software on the IP station.
TCIS Software Upgrade 4.PNG


The upgrade procedure takes about 3 minutes. The process can be monitored by clicking the Log viewer tab in the TFTP server program.

Troubleshooting

In the case where upgrade is not successful it may be due to a windows setting.

For Windows XP: http://www.sysprobs.com/enable-ping-in-xp

For Windows7: http://www.sysprobs.com/enable-ping-reply-windows-7

Coming

Upgrade from tsi-3.0.3.4 or older

To upgrade from version 3.0.3.4 or older to version 4.2.x.x is a two-step process:

1. Upgrade to 3.0.3.5 using the station web interface

  • Unzip the tsi-3.0.3.5.zip to a folder, and point to this folder in the TFTP Server.
  • In the station web, enter image file: tsi-3.0.3.5
  • Follow the instructions on the screen
Load tsi-3.0.3.5 via the station web interface



2. Upgrade to 4.2.3.0 using the station web interface

  • Unzip the sti-prod-4.2.3.0.zip to a folder, and point to this folder in the TFTP Server.
  • In the station web, enter image file: tsi2sti-4.2.3.0.ipk
Installing tsi2sti-4.2.3.0.ipk via the station web interface



3. Upgrade to 4.2.2.x using the station web interface