== Features ==
+
== Connections ==
* Designed to deliver CCoIP® - Critical Communication over IP
+
* [[IP Sub Connections|Intercom connections]]
* Weather and vandal resistant
 
* One vandal proof direct call button
 
* Station electronics available as kit for custom design
 
* Superb audio quality through wide bandwidth codec and high quality, high output power amplifier
 
* Integrated Web server
 
* Remote software upgrade, configuration and monitoring
 
* Line monitoring
 
* Dual Ethernet ports for [[Daisy chaining of IP Stations|daisy chaining IP stations]] or connection of other IP devices
 
* Possible connection to external IP video camera
 
* One relay output for door lock control or flash strobe light etc.
 
* External call button option
 
 
 
== Description ==
 
The STENTOFON Weather Resistant IP Substation is tough, durable and resilient, and designed for use in the harshest of environments. The station is typically used as a communication, information or emergency point and connects directly to the IP network making it easy to deploy – anywhere and at any distance.
 
 
 
Designed for CCoIP® the station offers a set of critical communication features such as integrated firewall, group call, call priority and override, to name just a few. This enables you to deliver instant, efficient and secure voice and data services in an IP environment.
 
  
The station provides superb wideband audio quality. If even higher audio volume is required, it is possible to interface the unit to an external power amplifier.
+
==Configuration==
 +
The station can operate in three different modes, depending on what kind of server the station should register to. Choose one of the links below according to what mode you need to configure.  
 +
* [[IP Station Configuration - ICX-AlphaCom mode]]
 +
* [[Adding station to existing system (Edge)|IP Station Configuration - Edge mode]]
 +
* [[SIP Intercom Configuration|IP Station Configuration - SIP mode]]
 +
* [[IP Station Configuration - Pulse mode]]
  
The station has one relay and one logical output. These outputs can, for instance, be used to open a door through a connected relay. The operation of the outputs is programmable and controlled by the AlphaCom E exchange.
+
== Restore Factory Defaults and Software Upgrade ==
 +
* [[INCA Station Restore Factory Defaults|Reset to factory settings]]
 +
* [[INCA Station Software upgrade|Upgrade via the station web interface]]
 +
* [[VS-IMT Upgrade Stations|Upgrade using the IMT tool]]
 +
* [[Automatic Software Upgrade|Automatic Software Upgrade (SIP mode only)]]
  
Further still, the station integrates into any AlphaCom E and upgraded AlphaCom solution, and is scalable from 2 to 1000’s of stations.
+
== Connectors, Indicators and Dimensions ==
 +
*[[INCA Substation Board Connectors|Board Connectors]]
 +
* [[INCA Substation LED Indicators|Station LED Indications]]
 +
* [[INCA Substation PCB LED Indicators|PCB LED Indications]]
 +
*[[IP Substation Dimensions & Mounting Instructions|Dimensions]]
  
== Specifications ==
+
== Accessories ==
[[Image:80411 - Specifications.PNG|800px|IP Sub 80411 Specifications]]
+
* [[Back box flush mount - 1008098100]]
{|border="1"
+
* [[Back box on wall mount - 1008098000]]
|Dimensions: (WxHxD) || 180 x 92 x 46 mm
 
|-
 
|Wight || 0.8 kg
 
|-
 
|Protection || Vandal resistant design, 2 mm stainless steel front, tamper proof loudspeaker grill, button and fastening screws
 
|-
 
|Protection Class || With mounting box 1008098000 (on wall): IP-44 <br/> With mounting box 1008098100 (flush mount):IP-55
 
|-
 
|Mounting || Flush mount in 50 mm deep back box
 
|-
 
|Temperature || -40˚C to +55˚C
 
|-
 
|Relative humidity || 0% - 95%
 
|-
 
|Power || Power over Ethernet, IEEE 802.3 a-f, Class 0 <br/> Local power 19-27 VDC, Idle 4W, max. 8W
 
|-
 
|Connectors || 2 x RJ45 (Ethernet) 10-100 Mbps <br/> Pluggable screw terminals (audio and I/O)
 
|-
 
|Remote control <br/> Max. switching capacity <br/> Max. voltage relay <br/> Max. current relay || 3 digital inputs, 1 relay output and one logical output <br/> 30W DC <br/> 60VDC <br/> 1A DC
 
|-
 
|SIP || RFC 3261, SIP Info (Cisco), RFC 2833 (DTMF)
 
|-
 
|IP Protocols || IP v4 - TCP - UDP - HTTPS - TFTP - RTP - RTPC - DHCP - SNMP - DiffServ - TOS - STENTOFON CCoIP® - SIP
 
|-
 
|LAN Protocols || Power over Ethernet (IEEE 802.3 a-f), VLAN (IEEE 802.1pq)*, Network Access Control (IEEE 802.1x)*, STP (IEEE 802.1d), RSTP (IEEE 802.1d-2004)
 
|-
 
|Audio Technology || Wideband 200 Hz - 7 kHz (G.722) <br/> Telephony 3.4kHz (G.711) <br/> Active noise filtering <br/> Acoustic echo cancellation <br/> Open duplex <br/> Adaptive jitter filter <br/> 1.5 Watt audio output <br/> 8 ohm loudspeaker impedance <br/> External audio out (0db, 600 ohm)
 
|-
 
|Management and Operation || HTTPS (Web configuration) <br/> DHCP and static IP <br/> Remote automatic software upgrade <br/> Centralized monitoring <br/> Status LED
 
|-
 
|Advanced features || Dual port managed data switch supporting VLAN and network access control
 
|-
 
|Compliance || CE and FCC Part 15
 
|}
 
 
 
== Indications ==
 
=== Station LED (on board and in front plate) ===
 
[[Image:IP substation connections.jpg|280px|right|IP Substation Connections]]
 
'''Blinking at 1 second interval''': Station does not have connection to the AlphaCom E exchange. <br>
 
''Possible reasons'':
 
* No connection to Ethernet
 
* Wrong AlphaCom E IP address configured
 
* Invalid IP address
 
* No or wrong gateway to the AlphaCom E exchange
 
 
'''Blinking at 5 seconds interval''': Station has connection to the AlphaCom E exchange, but has not been registered. <br>
 
''Reason'':
 
* Station has not been programmed in AlphaPro
 
 
 
'''No blinking'''<br>
 
''Possible reasons'':
 
* Station connected and registered to the AlphaCom E exchange - All OK
 
* Station not powered up (if no other LEDs are active)
 
 
 
=== Status LED ===
 
* '''Blinking 2 red + 1 green''': Station does not have connection to the AlphaCom E exchange
 
* '''Blinking 1 red + 2 green''':Station has connection to AlphaCom E exchange, but has not been registered
 
* '''Blinking 3 green''': Station connected and registered in the AlphaCom E exchange
 
 
 
=== LAN LEDs (on LAN and AUX RJ45-jacks) ===
 
'''Left green LED''':
 
* Steady light: Ethernet connection OK
 
* Blinking: Ethernet traffic
 
* No light: No Ethernet connection
 
'''Right amber LED''':
 
* Light: 100 Mbit Ethernet connection
 
* No light: 10 Mbit Ethernet connection
 
 
 
[[Category: Stations]]
 
[[Category: IP Stations]]
 
 
 
== Connections ==
 
[[Image:IP substation connections.jpg|280px|right|IP Substation Connections]]
 
There are four connectors on the IP substation board, P1-P4.
 
  
{|
+
== Software Requirements ==
|-
+
This station is fully supported as from AlphaCom version 10.20
|width="50pt" valign="top" |'''P1''':
 
|width="300pt"|RJ45 connector for LAN connection.
 
|-
 
| colspan="2" | The station can be powered from this connection if the line supports Power over Ethernet (PoE).
 
|-
 
| colspan="2" | &nbsp;
 
|-
 
|valign="top"|'''P2''': || RJ45 connector for auxiliary LAN equipment like TV camera, PC or a second IP station.
 
|-
 
| colspan="2" | This port has not an individual IP address or power for aux equipment.
 
|-
 
| colspan="2" | &nbsp;
 
|-
 
|'''P3''': || 6-pin plug-on screw terminal for external connections.
 
|-
 
|''Pin 1/2'': || Connect 24 VDC for station power if power is not distributed via LAN. Pin 1 is positive.
 
|-
 
|''Pin 3/4'': || Internal NO (Normal Open) relay contact for door lock control etc.
 
|-
 
|''Pin 5/6'': || Normally connected to station loudspeaker. May be used for 16-20 ohm/2 W external loudspeaker in parallel.
 
|-
 
| colspan="2" | &nbsp;
 
|-
 
|'''P4''': || 6-pin plug-on screw terminal for internal connections.
 
|-
 
| ''Pin 1/4'': || Call button no. 1.
 
|-
 
| ''Pin 2/4'': || Call button no. 2 if included
 
|-
 
| ''Pin 3/4'': || Call button no. 3 if included
 
|-
 
| ''Pin 5/6'': || Station LED for call and message info.
 
|-
 
| colspan="2" | &nbsp;
 
|-
 
| valign="top"|'''TP1/2''': || Optional external audio output.
 
|-
 
| colspan="2" | This is a 0 dB, 600 ohm balanced output for connection to a power amplifier. Note that the amplifier input MUST HAVE AN INSULATED INPUT (trafo, capacitors, etc.).
 
|-
 
|}
 
  
== Mounting ==
+
== Related information ==
*[[Back box on wall mount - 1008098000]]
+
* [http://www.zenitel.com/product/ip-vandal-resistant-substation-0 Additional Documentation on Zenitel.com]
*[[Back box flush mount - 1008098100]]
 
  
[[Category: Stations]]
+
[[Category: INCA Stations]]
[[Category: Vandal Resistant Stations]]
 
[[Category: IP Stations]]
 

Revision as of 14:18, 19 November 2020

AEPS.png
IP Substation, item 1008041100

Connections

Configuration

The station can operate in three different modes, depending on what kind of server the station should register to. Choose one of the links below according to what mode you need to configure.

Restore Factory Defaults and Software Upgrade

Connectors, Indicators and Dimensions

Accessories

Software Requirements

This station is fully supported as from AlphaCom version 10.20

Related information