[[image:80411 RS.jpg|thumb|250px|]]
+
{{AEPS}}
 +
[[image:80411 CC.PNG|right|175px|IP Substation, item 1008041100]]
 +
== Connections ==
 +
* [[IP Sub Connections|Intercom connections]]
  
== Features ==
+
==Configuration==
* Designed to deliver CCoIP® - Critical Communication over IP
+
The station can operate in three different modes, depending on what kind of server the station should register to. Choose one of the links below according to what mode you need to configure.
* Weather and vandal resistant
+
* [[IP Station Configuration - ICX-AlphaCom mode]]
* One vandal proof direct call button
+
* [[Adding station to existing system (Edge)|IP Station Configuration - Edge mode]]
* Station electronics available as kit for custom design
+
* [[SIP Intercom Configuration|IP Station Configuration - SIP mode]]
* Superb audio quality through wide bandwidth codec and high quality, high output power amplifier
+
* [[IP Station Configuration - Pulse mode]]
* Integrated Web server
 
* Remote software upgrade, configuration and monitoring
 
* Line monitoring
 
* Dual Ethernet ports for [[Daisy chaining of IP Stations|daisy chaining IP stations]] or connection of other IP devices
 
* Possible connection to external IP video camera
 
* One relay output for door lock control or flash strobe light etc.
 
* External call button option
 
  
== Description ==
+
== Restore Factory Defaults and Software Upgrade ==
The STENTOFON Weather Resistant IP Substation is tough, durable and resilient, and designed for use in the harshest of environments. The station is typically used as a communication, information or emergency point and connects directly to the IP network making it easy to deploy – anywhere and at any distance.
+
* [[INCA Station Restore Factory Defaults|Reset to factory settings]]
 +
* [[INCA Station Software upgrade|Upgrade via the station web interface]]
 +
* [[VS-IMT Upgrade Stations|Upgrade using the IMT tool]]
 +
* [[Automatic Software Upgrade|Automatic Software Upgrade (SIP mode only)]]
  
Designed for CCoIP® the station offers a set of critical communication features such as integrated firewall, group call, call priority and override, to name just a few. This enables you to deliver instant, efficient and secure voice and data services in an IP environment.
+
== Connectors, Indicators and Dimensions ==
 +
*[[INCA Substation Board Connectors|Board Connectors]]
 +
* [[INCA Substation LED Indicators|Station LED Indications]]
 +
* [[INCA Substation PCB LED Indicators|PCB LED Indications]]
 +
*[[IP Substation Dimensions & Mounting Instructions|Dimensions]]
  
The station provides superb wideband audio quality. If even higher audio volume is required, it is possible to interface the unit to an external power amplifier.
+
== Accessories ==
 +
* [[Back box flush mount - 1008098100]]
 +
* [[Back box on wall mount - 1008098000]]
  
The station has one relay and one logical output. These outputs can, for instance, be used to open a door through a connected relay. The operation of the outputs is programmable and controlled by the AlphaCom E exchange.
+
== Software Requirements ==
 +
This station is fully supported as from AlphaCom version 10.20
  
Further still, the station integrates into any AlphaCom E and upgraded AlphaCom solution, and is scalable from 2 to 1000’s of stations.
+
== Related information ==
 +
* [http://www.zenitel.com/product/ip-vandal-resistant-substation-0 Additional Documentation on Zenitel.com]
  
== Specifications ==
+
[[Category: INCA Stations]]
{|border="1"
 
|Dimensions: (WxHxD) || 180 x 92 x 46 mm
 
|-
 
|Weight || 0.8 kg
 
|-
 
|Protection || Vandal resistant design, 2 mm stainless steel front, tamper proof loudspeaker grill, button and fastening screws
 
|-
 
|Protection Class || With mounting box 1008098000 (on wall): IP-44 <br/> With mounting box 1008098100 (flush mount):IP-55
 
|-
 
|Mounting || Flush mount in 50 mm deep back box
 
|-
 
|Temperature || -40˚C to +55˚C
 
|-
 
|Relative humidity || 0% - 95%
 
|-
 
|Power || Power over Ethernet, IEEE 802.3 a-f, Class 0 <br/> Local power 19-27 VDC, Idle 4W, max. 8W
 
|-
 
|Connectors || 2 x RJ45 (Ethernet) 10-100 Mbps <br/> Pluggable screw terminals (audio and I/O)
 
|-
 
|Remote control <br/> Max. switching capacity <br/> Max. voltage relay <br/> Max. current relay || 3 digital inputs, 1 relay output and one logical output <br/> 30W DC <br/> 60VDC <br/> 1A DC
 
|-
 
|SIP || RFC 3261, SIP Info (Cisco), RFC 2833 (DTMF)
 
|-
 
|IP Protocols || IP v4 - TCP - UDP - HTTPS - TFTP - RTP - RTPC - DHCP - SNMP - DiffServ - TOS - STENTOFON CCoIP® - SIP
 
|-
 
|LAN Protocols || Power over Ethernet (IEEE 802.3 a-f), VLAN (IEEE 802.1pq)*, Network Access Control (IEEE 802.1x)*, STP (IEEE 802.1d), RSTP (IEEE 802.1d-2004)
 
|-
 
|Audio Technology || Wideband 200 Hz - 7 kHz (G.722) <br/> Telephony 3.4kHz (G.711) <br/> Active noise filtering <br/> Acoustic echo cancellation <br/> Open duplex <br/> Adaptive jitter filter <br/> 1.5 Watt audio output <br/> 8 ohm loudspeaker impedance <br/> External audio out (0db, 600 ohm)
 
|-
 
|Management and Operation || HTTPS (Web configuration) <br/> DHCP and static IP <br/> Remote automatic software upgrade <br/> Centralized monitoring <br/> Status LED
 
|-
 
|Advanced features || Dual port managed data switch supporting VLAN and network access control
 
|-
 
|Compliance || CE and FCC Part 15
 
|}
 
* Not supported in STENTOFON Pulse Mode
 
 
 
==Installation==
 
See article: [[IP Station Installation]]
 
 
 
==Station Board Connectors and LED Indications==
 
See article: [[IP_Station_Board_Connections_and_Indications#8022_-_IP_Substation|IP Station Board Connections and Indications]]
 
 
 
== IP Station Configuration ==
 
See article: [[IP_Station_Configuration#Configuration_in_IP-StationWeb]]
 
 
 
==Reset to factory settings==
 
See article: [[IP_Station_Restore_Factory_Defaults|IP Station Restore Factory Defaults]]
 
 
 
==Software Upgrade==
 
See article: [[IP Station Software upgrade]]
 
 
 
==Dimensions==
 
See article: [[IP_Stations_Dimensions_%26_Mounting_Instructions|IP Stations Dimensions and Mounting Instructions]]
 
 
 
 
 
[[Category: Stations]]
 
[[Category: Vandal Resistant Stations]]
 
[[Category: IP Stations]]
 

Revision as of 14:18, 19 November 2020

AEPS.png
IP Substation, item 1008041100

Connections

Configuration

The station can operate in three different modes, depending on what kind of server the station should register to. Choose one of the links below according to what mode you need to configure.

Restore Factory Defaults and Software Upgrade

Connectors, Indicators and Dimensions

Accessories

Software Requirements

This station is fully supported as from AlphaCom version 10.20