Actions

Difference between revisions of "Turbine 4.11 - Release notes"

From Zenitel Wiki

(Bugfixes and Improvements - VSF-Turbine 4.9.3.0)
(Known Issues - VSF-Turbine 4.9.3.1)
Line 19: Line 19:
 
== Bugfixes and Improvements ==
 
== Bugfixes and Improvements ==
  
==Known Issues - VSF-Turbine 4.9.3.1 ==
+
==Known Issues ==
===VSIS-878 Factory reset does not delete uploaded Script===
 
All uploaded scripts should also be removed on Factory reset
 
 
 
===MTN-1964 Tone volume not working for tone test===
 
There was an error in the tone test that caused the Tone volume to be ignored. The Tone volume was always equal to the speaker volume.
 
 
 
===MTN-2073 Turbine Sound detection (VAD) does not trigger correctly===
 
Minimum Amplitude setting under the Turbine Sound Detection setting doesn't take effect. Reboot Main Application or System reboot doesn't have any effect. 
 
 
 
<br><br>
 
  
 
==Known Issues - VSF-Turbine 4.9.3.0 ==
 
==Known Issues - VSF-Turbine 4.9.3.0 ==

Revision as of 15:15, 9 January 2019

Release info

Name: VSF-Turbine
Description: VSF-Turbine is a firmware archive for all Turbine Family Intercom stations including devices: TCIS-x, TKIS-2, TCIV-x, TMIS-x, TFIE-x, TKIE-x, TFIX-x, ECPIR-3P, ENA-2060AC (only in SIP mode), Exigo IP speakers and Exigo Network Amplifiers (AlphaCom mode only).
Version: The firmware is delivered in two different ZIP archives:

  • vsft-4.11.2.x - Used for standard in-field upgrades
  • vsft-prod-4.11.2.x - Used in production- and recovery upgrades.

Version: 4.11.2.5
Date: 15.01.2019
Status: Limited Availability

VSF-TURBINE 4.11.2.5

New Features - Turbine Intercom

New Features - Exigo Network Amplifiers

Technical Preview

Bugfixes and Improvements

Known Issues

Known Issues - VSF-Turbine 4.9.3.0

MTN-598 IP station fails to register if Hebrew name is too long

More than 12 characters entered causes registration problems

MTN-1077 Lamp test not functioning on ECPIR-3P and belonging EBMDR-8

Alphacom DAK Lamp test (feature 7874) not implemented on DAK Panel ECPIR-3P and belonging EBMDR-8

MTN-1073 Group call fails if system previously configured with ZAP

If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.

MTN-268 Relay follow M-key cannot handle quick M

Relay configured to follow M-key does not handle quick press on M-key

MTN-1503 Changing the Detailed Logging setting disables syslog logging

If Detailed Logging is enabled or disabled, the syslog functionality doesn't work - Turbine log messages do not arrive on the syslog server. Workaround: Changing Log level setting for syslog will enable the syslog logging again

VSIS-878 Factory reset does not delete uploaded Script

All uploaded scripts should also be removed on Factory reset

SNOW-579 TFIE-6 does not display AlphaCom status-messages in Idle

There is no way of knowing if a TFIE-6 is for example forwarded(71,72) or marked absent(77x). Workaround: During commissioning it is possible by Class Of Service programming in AlphaCom to deny access to these services for the TFIE-6