Door opening of Ring Master stations from AlphaCom is configured by using Event During Connection and DP message DTMF_CONN

Example

Node 1 AlphaCom

Node 3 Ring Master

Event During Connection configured as directory number "6" (Door opening)

The Event Handler configured with 2 events:

The first event will send DTMF tone 5 if digit "6" is pressed during conversation to "4567".

Event Trigger Feature 15

  • Owner Station 1
  • Related to Node 3 and directory number "4567"

Event string:

  • $DTMF_CONN L%1.phy U5

The second event will toggle the RCO pin 4 for 1 second if digit "6" is pressed during conversation to door station number 4.

Event Trigger Feature 15

  • Owner Station 1
  • Related to local Station 4

Event string: