Door opening of Ring Master stations from AlphaCom is configured by using Event During Connection and DP message DTMF_CONN

Example

Node 1 AlphaCom

Node 3 Ring Master

Event During Connection configured as directory number "6" (Door opening)

The Event Handler is configured with 2 events:


Event 1: This event will send DTMF tone 5 if digit "6" is pressed during conversation to "4567".

Event Owner: Station Id: 1
Event type: 15 - Event Trigger Feature
Subevent: 0
When change to: ON or OFF
When related to: Node: 3, Directory Number, Id: 4567
Action: $DTMF_CONN L%1.dir U5

Event 2:The second event will toggle the RCO pin 4 for 1 second if digit "6" is pressed during conversation to door station number 104.

Event Owner: Station Id: 1
Event type: 15 - Event Trigger Feature
Subevent: 0
When change to: ON or OFF
When related to: Directory Number, Id: 104