* Station 104 is a [[Vandal Resistant Substation - 1007056100|Door Station]]
 
Node 3 Ring Master
 
Node 3 Ring Master
* [[Door Station]] Directory number "4567"
+
* Door Station Directory number "4567"
  
 
[[Event During Connection]] configured as directory number "6" (Door opening)  
 
[[Event During Connection]] configured as directory number "6" (Door opening)  

Revision as of 14:20, 3 November 2016

Door opening of Ring Master stations from AlphaCom is configured by using Event During Connection and DP message DTMF_CONN

Example

Node 1 AlphaCom

Node 3 Ring Master

  • Door Station Directory number "4567"

Event During Connection configured as directory number "6" (Door opening)

The Event Handler is configured with 2 events:


Event 1: This event will send DTMF tone 5 if digit "6" is pressed during conversation to "4567".

Event Owner: Station Id: 1
Event type: 15 - Event Trigger Feature
Subevent: 0
When change to: ON or OFF
When related to: Node: 3, Directory Number, Id: 4567
Action: $DTMF_CONN L%1.dir U5

Event 2:The second event will toggle the RCO pin 4 for 1 second if digit "6" is pressed during conversation to door station number 104.

Event Owner: Station Id: 1
Event type: 15 - Event Trigger Feature
Subevent: 0
When change to: ON or OFF
When related to: Directory Number, Id: 104
Action: RCO 4 ON U10


Related Article: RingMaster/AlphaCom Integration - DTMF