[[File:IP Video Door Station.PNG|thumb|600px|IP Video Station, item 1401110100]]
+
{{Obsolete}}
 +
{{AEIPS}}
 +
[[File:IP Video Door Station.PNG|thumb|600px|IP Video Station with CP-CAM camera, item 1401110100]]
  
The STENTOFON Vandal Resistant '''IP Video Station''' (item 1401110100) is tough, durable and resilient, and designed for use in the harshest of environments. The station is typically used as a communication, information or emergency point and connects directly to the IP network making it easy to deploy – anywhere and at any distance. Designed for CCoIP® the station offers a set of critical communication features such as integrated firewall, group call, call priority and over-ride, to name just a few. This enables you to deliver instant, efficient and secure voice, video and data services in an IP environment.
+
== Connections ==
 +
* [[IP Video Doorstation Connections|Intercom connections]]
  
=Configuration=
+
==Configuration==
==CCoIP Station==
+
The station can operate in three different modes, depending on what kind of server the station should register to. Choose one of the links below according to what mode you need to configure.  
The station must be given an IP address, either static or one provided by a DHCP server. In addition the IP address of the AlphaCom and the directory number must be set. This is all done in the inbuilt webserver.  
 
  
For more details, please see: [[IP_Station_Configuration#Station_Main_Settings|IP Station IP and Server configuration]]
+
General configuration:
 +
* [[IP Station Configuration - ICX-AlphaCom mode]]
 +
* [[Adding station to existing system (Edge)|IP Station Configuration - Edge mode]]
 +
* [[SIP Intercom - Web Interface|IP Station Configuration - SIP mode]]
 +
* [[IP Station Configuration - Pulse mode]]
  
<br style="clear:both;" />
+
Station specific configuration:
 +
* [[CP Cam Configuration]]
  
==Camera==
+
== Restore Factory Defaults and Software Upgrade ==
Connect to the camera using a webbrowser on default IP address 169.254.1.101.
+
* [[INCA Station Restore Factory Defaults|Factory reset of the intercom station]]
 +
* [[CP-Cam Factory Reset|Factory reset of the Camera Module]]
 +
* [[INCA Station Software upgrade|Upgrade via the station web interface]]
 +
* [[IMT - Discover & Upgrade|Upgrade using the IMT tool]]
 +
* CP Cam upgrade
 +
* [[Automatic Software Upgrade|Automatic Software Upgrade (SIP mode only)]]
 +
* [[:Category:INCA Release notes|Software Release Notes]]
  
In the menu that appears, click '''System Settings''', and you will be asked to login:
+
== Connectors, Indicators and Dimensions ==
 +
*[[INCA Video Doorstation Board Connectors|Board Connectors]]
 +
* [[INCA Video Doorstation LED Indicators|Station LED Indications]]
 +
* [[INCA Substation PCB LED Indicators|PCB LED Indications]]
 +
* [[IP Video Doorstation Dimensions & Mounting Instructions|Dimensions]]
  
Username: '''admin''' <br/>
+
== Accessories ==
Password: '''1234'''
+
* [[Back box flush mount - 1401199101]]
 +
* [[Back box on wall mount - 1401199111]]
 +
* [[Protection Roof - 1401199112]]
  
Set to factory default:
+
== Software Requirements ==
===CP-Cam Factory Reset===
+
This station is fully supported as form AlphaCom version 10.20
'''This should be carried out only by experienced technicians. The customer is liable for damages caused by improper opening of the housing. '''
 
  
If the entered IP address is unknown, it is possible to reset the address to 169.254.1.101 using the DIP switch. To proceed, the unit must be opened.
+
== Additional information ==
''Note: A change of the IP address is made via the web interface of the CP-CAM.''
+
* [http://www.zenitel.com/product/ip-vandal-resistant-video-intercom-station-w-cp-cam-camera Additional Documentation on Zenitel.com]
The procedure is as follows:
 
:1. Open the CP-CAM so the two DIP switches are accessible ( see picture ).
 
:2.  Note the switch position and then turn both switches to „OFF“.
 
:3.  Connect PC with the IP number range 169.254.1.xxx and set the desired IP address in the web interface.
 
:4.  Turn switch positions back to original positions.
 
:5.  Close housing properly.
 
  
[[File:CP-CAM.PNG|thumb|500px|left]]
 
<br style="clear:both;" />
 
  
=Setup with STENTOFON Video Display Station=
+
[[Category: Discontinued Stations]]
To configure the STENTOFON Video Display Station please see: [[IP Desktop Station with Video Display - 1408001635]]
 
 
 
This chapter describes the steps for configuring the CP-Cam:
 
 
 
From the Main Menu select '''System Settings > Network'''
 
:1. Under section '''IP-SETUP''', set ''IP-SETUP Type'' to '''Manual'''
 
[[File:IP-VideoDoorStation1.png|left|thumb|500px]]
 
<br style="clear:both;" />
 
:2. Enter a static IP adresss, Netmask, Gateway and DNS
 
:3. Under section '''System''', set ''Authentication required for Picture/Video'' to '''No'''
 
[[File:IP-VideoDoorStation2.png|left|thumb|500px]]
 
<br style="clear:both;" />
 
:4. Click '''Save Changes''' at the bottom of the page
 
<br style="clear:both;" />
 
----
 
 
 
From the Main Menu select '''System Settings > Camera'''
 
:1. Under section '''Settings''', set ''Mode'' to '''Custom'''
 
:2. Set '''Res X''' to 320
 
:3. Set '''Res Y''' to 240
 
[[File:IP-VideoDoorStation3.png|left|thumb|500px]]
 
<br style="clear:both;" />
 
:4. Under section '''Settings''', set ''Frames per Second (Sensor)'' to '''15'''
 
[[File:IP-VideoDoorStation4.png|left|thumb|500px]]
 
<br style="clear:both;" />
 
 
 
=Setup with 3rd party Video devices=
 
==SNOM IP Phones==
 
The video image of the IP Video Door Station can be displayed on a Snom IP phone display. Following possibilities can be realized:
 
* '''Manual video image'''. The video image of the IP Video Door Station can be activated and ended by key press.
 
* '''Pop up video image'''. The video image of IP Video Door Station is shown automatically on an incoming call and end automatically when the communication is finished.
 
 
 
 
 
Conditions for displaying a video image by an incoming call:
 
*Compatible Snom phone (models 820, 821, 760)
 
* Registration on an AlphaCom, PULSE server or SIP-server.
 
* Snom firmware must be version 8.7.4.5t.
 
 
 
=== AlphaCom configuration ===
 
The Snom phone must be configured as a SIP User in AlphaPro, '''Users & Stations'''. See article [[SIP phone as station]] for details.
 
 
 
 
 
=== Firmware update of Snom phone===
 
 
 
The firmware of the Snom phone must be uploaded using a TFTP server. Upgrade procedure:
 
* Download the software 8.7.4.5t from the [[Downloads#IP_Video_stations|AlphaWiki download site]]
 
* Unzip the file. Remember in which folder you stored the file
 
* Start a TFTP server, and browse to the folder which contains the file
 
* In the Snom webinterface, select '''Software Update''' and enter address ''tftp://[TFTPServer]/[file name],'' where ''[TFTPServer]'' = IP address of PC running the TFTP server and ''[file name]'' is the name of the downloaded .bin file. Example: '''tftp://10.5.101.129/snom821-8.7.4.5t-SIP-r.bin'''.
 
* Select '''Load''', and watch the progress on the display of the Snom phone
 
[[File:SnomVideo11.png|thumb|500px|left|Starting the software upgrade process]]
 
<br style="clear:both;" />
 
 
 
=== Network and SIP account in Snom phone ===
 
Factory default of the phone is done from the phones keyboard by pressing:
 
* The button Menu
 
* 5 - Maintenance
 
* 4 - Reset Values
 
* Enter default  password '''0000'''. The phone will restart.
 
 
 
Follow the display setup wizard to set:
 
* Language
 
* Time Zone
 
* Tone scheme
 
* SIP Account = Directory number in AlphaCom
 
* Registrar = IP address of AlphaCom
 
* Select DHCP or enter IP settings of phone
 
 
 
The phone must be rebooted after this.
 
 
 
SIP account settings can be changed in '''Identity 1''' in web access.
 
IP settings are changed in '''Advanced''' -> '''Network'''.
 
 
 
=== Codec settings ===
 
Codec must be changed to G.711u-law (pcmu) and the internal "telphone event".
 
 
 
In '''Identity 1''' -> '''RTP''', set the codec to: "pcmu,telephone-event", remove all other codecs:
 
[[File:SnomVideo8.png|thumb|500px|left|Set the codec to: "pcmu,telephone-event"]]
 
<br style="clear:both;" />
 
 
 
=== Pop up video image ===
 
The screen display in the XML-Mini-Browser of Snom IP phones can be started and ended automatically. The following settings are necessary.
 
 
 
==== Configuration in Snom Phone ====
 
Firmware version 8.7.4.5t-SIP-r for the Snom phones 820, 821, 760 is required to get video pop up.
 
 
 
The IP Video Door Station(s) must be defined in the Directory of the Snom phone.
 
 
 
In the web interface of the phone, select '''Directory''' in the menu, and enter the following parameters:
 
* '''Number''': The directory number of the IP Video Door Station, as entered in AlphaPro, Users & Stations.
 
* '''Title''': Enter any text
 
* '''Action URL''': <nowiki>http://<IP adress of the camera>/snoma.cgi. For example http://10.5.101.97/snoma.cgi</nowiki>
 
* '''Nickname''': Enter any text
 
 
 
 
 
[[File:SnomVideo4.png|thumb|500px|left|Configure the IP Video Door station in the Directory list of the Snom phone]]
 
<br style="clear:both;" />
 
 
 
 
 
Set "Call Waiting Indication" to "Off":
 
[[File:SnomVideo5.png|thumb|500px|left|Set "Call Waiting Indication" to "Off"]]
 
<br style="clear:both;" />
 
 
 
 
 
Set SIP port to 5060:
 
[[File:SnomVideo6.png|thumb|500px|left|Set SIP port to 5060]]
 
<br style="clear:both;" />
 
 
 
 
 
 
 
 
 
Disable "Filter packets from Registrar":
 
[[File:SnomVideo7.png|thumb|500px|left|Disable "Filter packets from Registrar"]]
 
<br style="clear:both;" />
 
 
 
 
 
====Configuration of the camera ====
 
In the camera the authentication for the image/video display has to be deactivated.
 
Log on to the camera (default username: '''admin''', password: '''1234'''). Under '''System Settings'''->'''Network'''->'''System''', change the "''Authentication required for Picture/Video''" to "No".
 
 
 
 
 
[[File:SnomVideo2.png|thumb|500px|left|Select '''System Settings''', then '''Network'''.]]
 
<br style="clear:both;" />
 
 
 
 
 
[[File:SnomVideo3.png|thumb|500px|left|Switch off the authentication.]]
 
<br style="clear:both;" />
 
 
 
 
 
Set the resolution to match the video display of the Snom phone, 320 x 240 pixels:
 
 
 
[[File:SnomVideo12.png|thumb|500px|left|Set resolution to QVGA 320 x 240.]]
 
<br style="clear:both;" />
 
 
 
==== Operating the Door Opening relay ====
 
During conversation with the IP Video Door Station the integrated relay of the door station can be operated by pressing digit 6 on the Snom phone. The Snom phone uses DTMF by RFC2833 by default, which is supported by AlphaCom, so no settings are required in the phone.
 
 
 
In AlphaCom the relay must be mapped to a logical RCO, and an "Door Opening" event created to trigger this RCO.
 
 
 
To map a logical RCO to the relay of the IP Station, select '''Exchange & System''' -> '''RCO'''. Pick a free RCO, select Change and set the RCO Type = Station, enter the physical number of the IP Station, and set pin number = 1. In the example below the relay of IP Video Door station 48 (directory number 148) is mapped to RCO 11.
 
<br/>
 
[[File:SnomVideo10.png|thumb|500px|left|Logical RCO 11 is mapped to the relay of station 48]]
 
<br style="clear:both;" />
 
 
 
 
 
Create a "Door Opening" event with the IP Video Door Station as the event owner. Select '''Exchange & System''' -> '''Events''', and '''Insert''' a new event with the following properties:
 
 
 
[[File:SnomVideo9.png|thumb|500px|left|During conversation with the door station (148), pressing digit 6 will trigger the relay (RCO 11)]]
 
<br style="clear:both;" />
 
For connection details, see article: [[IP Station Board Connections and Indications]]
 
 
 
 
 
 
 
 
 
===Manual video image (Optional) ===
 
The video image of the IP Video Door Station in the Snom IP phones can be started and ended manually by pressing a function key. With this feature the video image can be displayed without setting up a conversation.
 
====Configuration of the Snom phone ====
 
In the web interface of the phone, select '''Function Keys''' in the menu, and enter the following parameters:
 
* '''Context''': Active
 
* '''Type''': Action URL
 
* '''Number''': <nowiki>http://<IP adress of the camera>/snoma.cgi. For example http://10.5.101.97/snoma.cgi</nowiki>
 
* '''Short text''': Enter any text
 
 
 
 
 
[[File:SnomVideo1.png|thumb|500px|left|Pressing function key 1 will start the video image from camera 10.5.101.97]]
 
<br style="clear:both;" />
 
 
 
==== How to use ====
 
 
 
* '''Start video image''': The video image is started by pressing the programmed key.
 
* '''End video image''': The video image is ended by pressing the "X-key".
 
 
 
 
 
==== Authentication ====
 
 
 
If the access of the camera is to be password protected, the following adjustments are necessary.
 
 
 
'''Configuration of the Snom phone'''<br>
 
 
 
In the web interface of the phone, select '''Function Keys''' in the menu, and enter the following parameters:
 
* '''Context''': Active
 
* '''Type''': Action URL
 
* '''Number''': <nowiki>http://<User name>:<Password>@<IP adress of the camera>/snoma.cgi. If for example username is "viewer" and the password is "1234", enter http://viewer:1234@10.5.101.97/snoma.cgi</nowiki>
 
* '''Short text''': Enter any text
 
 
 
 
 
'''Configuration of the camera'''<br>
 
 
 
In the camera the authentication for the image/video display has to be activated. Under '''System Settings'''->'''Network'''->'''System''', change the "''Authentication required for Picture/Video''" to "Yes".
 
 
 
==Milestone==
 
It is assumed that a Milestone XProtect system is already installed and up and running. The latest Milestone XProtect Professional and Smart client can be downloaded from Milestonesys.com.
 
 
 
The version used in the examples that follows is XprotectPro V8.1a
 
 
 
Open the XProtect Professional Management Application by double clicking the desktop icon. Expand the mennu tree strcture and right click ''Hardware Devices''. Select '''Add New Hardware Device'''
 
[[File:Milestone4.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
Choose '''Manual''' as the hardware detection method.
 
[[File:Milestone5.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
*1 Enable ''Use''
 
*2 Type in the IP address of the camera in the ''Address'' field
 
*3 Select username '''admin''' from the dropdown box under ''User Name''
 
*4 Enter the default IP Video Door Station camera password: 1234 in the ''Password field''
 
*5 In the ''Hardware Driver'' dropdown box, scroll down and select '''Universal Driver'''
 
*6 Repeat for 1-5 the next camera(s)
 
*7 Click '''Next''', followed by '''Finish''' in the next window.
 
[[File:Milestone6.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
After adding the new camera(s) to the device list, they should appear in the tree structure under ''Cameras and Storage Information''. Right click the IP Video Station camera and select '''Properties'''
 
[[File:Milestone3.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
If the image in the preview window is visible, no more actions are required.
 
 
 
If there is no image shown from the camera, click on the ''Camera Settings...'' button.
 
[[File:Milestone2.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
In the Video Properties set:
 
*1 Codec: JPEG
 
*2 Streaming mode: HTTP
 
*3 Delivery mode: Multipart stream
 
*4 Retrieval mode: Streaming
 
*5 Connection URI: <nowiki>http://<camera IP address>/mjpg/video.mjpg</nowiki>
 
*6 Click ''Preview Image'' to verify that the image is shown, followed by clicking ''OK''.
 
[[File:Milestone1.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
 
 
 
 
 
 
[[Category: Stations]]
 
[[Category: IP Stations]]
 
 
[[Category:Video]]
 
[[Category:Video]]

Latest revision as of 09:24, 16 August 2022

Obsolete icon This product is discontinued!


AEIPS.png
IP Video Station with CP-CAM camera, item 1401110100

Connections

Configuration

The station can operate in three different modes, depending on what kind of server the station should register to. Choose one of the links below according to what mode you need to configure.

General configuration:

Station specific configuration:

Restore Factory Defaults and Software Upgrade

Connectors, Indicators and Dimensions

Accessories

Software Requirements

This station is fully supported as form AlphaCom version 10.20

Additional information